![SMS RED-G 3000 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/sms/red-g-3000/red-g-3000_user-manual_1306768037.webp)
RED-G
37
REV.9 PRINTED 02/2018
Led A
Led B
Description
Notes
RED-G not ready (4th Pole open)
RED-G ready to rescue operation
Rescue operation in progress
Rescue operation ended
x
x
Maximum operating time expired
x
Contactors “locked on”
x
Contactors not energized
Wrong Battery voltage
Wrong Control circuit supply voltage
Inverter Overcurrent
x
Medium current too High
Overload
I/O ELECTRICAL SPECIFICATIONS INPUTS
- Brake Voltage: Allowed Voltage 48 ÷ 230Vdc +/-10%
- Contacts 4P – ON: Rated Voltage 60Vdc max.
Minimum Switching Current 5mA
BATTERY CHARGER BOARD “BACH” LAYOUT
TECHNICAL SPECIFICATIONS
Power Supply: 230V 50Hz / 60Hz +8/-15%
Input Current: 0,8A
Output Current: 2.5A
LEDS
CB - GREEN Battery Charger working
BI - RED Battery with reversed polarity
OUTPUTS
- Contacts KE – FA:
Switching Load 24Vdc/8A 250Vac/8A
110Vdc/0,3A
Minimum Switch. Load: 5V/5mA
B
ATTERY
C
HARGER
B
OARD
“B
ACH
” L
AYOUT
/ B
ATTERY
C
HARGER
B
OARD
“B
ACH
L
AYOUT
=Led OFF
=Led ON
=Led Flashing slowly
=Led Flashing fast
=
Led Flashing very slowly (2”)
Содержание RED-G 3000
Страница 39: ...RED G 39 REV 9 PRINTED 02 2018 RED G 3000 INTERNAL DIAGRAM RED G 3000 BOARD SETTINGS 003 11 0500200M...
Страница 40: ...RED G 40 REV 9 PRINTED 02 2018 RED G 4000 INTERNAL DIAGRAM RED G 4000 BOARD SETTINGS 003 11 0500700M...
Страница 41: ...RED G 41 REV 9 PRINTED 02 2018 RED G 8000 INTERNAL DIAGRAM RED G 8000 BOARD SETTINGS 003 08 B0039 003 07 AB400...
Страница 43: ...RED G 43 REV 9 PRINTED 02 2018...