10
Fig. 19: Adjusting the Pre-Runtime
Fig. 20: Adjusting the pump value.
Abb. 22: Exiting the profile
Fig. 21: Startuing the profile
You can adjust the variables according to the menu items 1 - 7 (see
above table), by pressing the Mode button until you reach the required
function and adjusting the values with the Up/Down-buttons.
Press and hold the Mode button on the control panel until “
Pro”
appears
on the display (see fig. 12)
5.3.4 „Timer“ Haze-Density Control System (HDCS)
With the
HDCS
it is possible to specify a certain user profile.
Two levels (A and B) can be regulated, the haze time and wait time can be adjusted in minutes the pump and the fan
output can be adjusted in percent.
Level A
= Menu Item 2, 3, 4
Level B
= Menu Item 5, 6, 7
Additionally you can adjust the hazing time (Menu Item 1).
Example:
The device has to start hazing after 30 minutes (Menu Item 1). The stage has to be hazed for a period of
10 minutes. To fulfil these requirements a high pump and fan output is required as well as a hazing time of 10 minutes
(Menu Item 2, 3 and 4). After 10 minutes the pump and the fan have to be turned off and the stage must be hazed
another one hour (Menu Items 5, 6 and 7).
Following menu items can be adjusted
1. Pause (Pre-Runtime) 0 - 99 min
2. Pump (level A)
1 - 99 %
3. Fan (level A)
1 - 99 %
4. Run-Time (level A)
0 - 99 min
5. Pump (level B)
1 - 99 %
6. Fan (level B)
1 - 99 %
7. Run-Time (level B)
0 - 99 min
Press and hold the mode button until „run“ appears on the display (fig. 21).
Pressing and holding the Enter-buttons starts the specifically created user
profile.
Press and hold the menu button once to get to the HDCS-Menu Item. The
red Timer/Profile-LED is lit up.