10

Fig. 19: Adjusting the Pre-Runtime

Fig. 20: Adjusting the pump value.

Abb. 22: Exiting the profile 

Fig. 21: Startuing the profile 

You can adjust the variables according to the menu items 1 - 7 (see 

above table), by pressing the Mode button until you reach the required 

function and adjusting the values with the Up/Down-buttons. 

Press and hold the Mode button on the control panel          until “

Pro” 

appears 

on the display (see fig. 12) 

5.3.4 „Timer“ Haze-Density Control System (HDCS) 

With the 

HDCS

 it is possible to specify a certain user profile. 

Two levels (A and B) can be regulated, the haze time and wait time can be adjusted in minutes the pump and the fan 
output can be adjusted in percent. 

Level A

 = Menu Item 2, 3, 4  

Level B

 = Menu Item 5, 6, 7 

Additionally you can adjust the hazing time (Menu Item 1). 

Example:

 The device has to start hazing after 30 minutes (Menu Item 1). The stage has to be hazed for a period of 

10 minutes. To fulfil these requirements a high pump and fan output is required as well as a hazing time of 10 minutes  
(Menu Item 2, 3 and 4). After 10 minutes the pump and the fan have to be turned off and the stage must be hazed 
another one hour (Menu Items 5, 6 and 7).  

Following menu items can be adjusted 

1. Pause (Pre-Runtime)   0 - 99 min 
2. Pump (level A)  

1 - 99 % 

3. Fan (level A)    

1 - 99 % 

4. Run-Time (level A)  

0 - 99 min

5. Pump (level B)  

1 - 99 % 

6. Fan (level B)    

1 - 99 % 

7. Run-Time (level B) 

 0 - 99 min

Press and hold the mode button until „run“ appears on the display (fig. 21). 

Pressing and holding the Enter-buttons starts the specifically created user 

profile. 

Press and hold the menu button once to get to the HDCS-Menu Item. The 

red Timer/Profile-LED is lit up.  

Содержание Tour Hazer II

Страница 1: ...0 See the Performance Introduction Manual Type Tour Hazer II...

Страница 2: ...3 2 DMX512 Control 5 3 2 1 Adjusting DMX Start address 5 3 2 2 Adjusting pump and fan output 8 9 9 5 3 3 Standalone Control 9 5 3 4 Controlling the device with Timer HDCS 10 5 4 Autostart 5 5 Pin Conf...

Страница 3: ...that you will use simply and safely Thank you for placing your trust in us Read and understand the safety precautions before operating the machine Failure to properly follow these instructions may lea...

Страница 4: ...droplets can cause slip hazard Mop up the fluid and dispose of it according to regulations SMOKE FACTORY fluid is completely watersoluble and biodegradable Artificially made fog can be produced in ma...

Страница 5: ...ACTORY fog generator Scotty II or Fire Trainer It doesn t matter You get the equipment that makes the difference 1 Control panel for adjusting the DMX start address and the output 2 Fog emission 3 Air...

Страница 6: ...sinter filter Pin Configuration See page 11 1 3 2 4 5 6 1 Control panel 2 Label Type 3 Safety guard Entrapped air fort he fan 4 Air deflector rotatable 5 Connection area Power Controls Medium 6 Canist...

Страница 7: ...ed Use of other liquids will lead to clogging an void the manufacturer s warranty Don t use fluid older than five years Fog fluid cannot be stored for an indefinite period of time If you wish more inf...

Страница 8: ...a real Touring Hazer With its 1500 W it is a truly powerful smoke machine Due to the digital technique it is possible to generate tiny clouds as well as roomfilling fog The performance of the fog gen...

Страница 9: ...ower supply too early Otherwise the tubes and HE cannot be cleaned properly 5 3 Control System 5 3 1 External Control 5 3 2 Operating via DMX 512 You may control the Tour Hazer II externally through t...

Страница 10: ...be adjusted directly at the machine Press the Mode button at the control panel until a P and two figures appear on the LED display Adjust the desired data 1 99 by pressing the Up Down Button By pressi...

Страница 11: ...enu Item 5 6 7 Additionally you can adjust the hazing time Menu Item 1 Example The device has to start hazing after 30 minutes Menu Item 1 The stage has to be hazed for a period of 10 minutes To fulfi...

Страница 12: ...and hold the Mode button until you see ESC on the display Fig 22 and press the Enter button 5 4 Autostart If the Timer is activated but the device disconnected from the mains supply Tour Hazer II will...

Страница 13: ...me to time and clean or replace it when necessary CAUTION The evaporator of our devices must not be cleaned as the cleaning substances can fundamentally damage the evaporator This leads to a loss of t...

Страница 14: ...vates itself The over temperature protection device is activated Remove external heat sources to maintain air supply The device will reactivate as soon as the normal operating temperature is reached T...

Страница 15: ...steps Control options DMX 512 0 10 V Analog Timer Standalone XLR Remote Optional Heating up time Approximately 1 minute Temperature controlling Microprocessor Overheating protection Heater block with...

Страница 16: ...en used or if units are sent to us with full fluid bottles Also non compliance with the instructions in this manual or mistakes by incorrect handling treating of the machine will lead to a loss of gua...

Страница 17: ...enhagen Hannover Tel 49 0 511 51 51 02 0 Fax 49 0 511 51 51 02 22 Email info smoke factory de Internet www smoke factory de Responsible for content Fog Smoke Haze Factory GmbH Design Arrangement www d...

Отзывы: