TRAK MODEL 9100 MODULAR FREQUENCY/TIME SYSTEM
2-8
TM4400013
Rev.
D
Table 2-9, TEL Framing Format Switch Positions for T1
S1 Settings
On
Off
S1-4
B8ZS Disabled
B8ZS Enabled
S1-5 Transparent
Zero
Suppression
Bit 7 Stuffing Zero
Suppression
S1-6 Yellow
Alarm
Transmit Disabled
Yellow Alarm
Transmit Enabled
S1-7
193S Select
193E Select
S1-8
Internal 193S Bit
Selection
External 193S Bit
Selection
Table 2-10, TEL Line Length Compensation
Switch Positions for T1
S1-1
Settings
S1-2
Settings
S1-3
Settings
Line Length
On
Off
Off
1 – 133 Feet
Off
On
On
133 – 266 Feet
Off
On
Off
266 - 399 Feet
Off
Off
Off
399 – 533 Feet
Off
Off
Off
533 – 655 Feet
Model 9111 TEL Module Switch and Jumper Settings for E1
Output Ground Isolation (Factory configured)
R33 – R36 Zero Ohm resistors not installed (Isolated), for balanced 120
Ω
output
R33 – R36 Zero Ohm resistors installed (non-Isolated), for unbalanced 75
Ω
output
Clock Select (Factory configured)
J3, jumper pins 2 and 3 (2.048 MPPS)
Output Transformer Impedance Select (Factory configured)
J5 – J8, jumper 1 and 2 (120
Ω
)
J5 – J8, jumper 2 and 3 (75
Ω
)
Table 2-11, TEL Framing Format Switch Positions for E1
S1 Settings
On
Off
S1-4 Transmit
CAS
M frame enabled
Transmit CAS
M frame disabled
S1-5 Transmit
CRC4
M frame disabled
Transmit CRC4
M frame enabled
S1-6
Data AMI encoded
Data HDB3 encoded
S1-7
TDMA normal
TDMA alarm enable
S1-8
TRA normal
TRA alarm enable
Содержание TRAK 9100
Страница 4: ...TRAK MODEL 9100 MODULAR FREQUENCY TIME SYSTEM TM4400013 Rev D ii Frequency Time Systems Model 9100 ...
Страница 59: ...B 1 TM4400013 REV D APPENDIX B Model 9100 NTS Option ...
Страница 71: ...TRAK MODEL 9100 MODULAR FREQUENCY TIME SYSTEM C 1 TM4400013 REV D APPENDIX C TIME CODE FORMATS ...
Страница 86: ...TRAK MODEL 9200 MODULAR FREQUENCY TIME SYSTEM TM4400013 REV D APPENDIX F Model 9200 Manual ...
Страница 109: ...TRAK MODEL 9100 MODULAR FREQUENCY TIME SYSTEM H 1 TM4400013 REV D APPENDIX H CE Compliance Certificate ...