Smith-Root VVP-15C Скачать руководство пользователя страница 5

3

USER’S GUIDE

2015

1. 

SECONDS:

 LCD timer. Shows 

accumulated electrofishing 
time since last reset.

2. 

OUTPUT STATUS INDICATORS 

(3):

OUTPUT ON:

 Red indicator 

light indicates that the output 
from the unit is ON.

OUTPUT OFF:

 Green indicator 

light indicates that the output 
from the unit is OFF.

OVERLOAD:

  Red indicator 

light indicates average or peak 
output current overload.

3. 

ELECTRODE SELECTOR:

 This 

switch selects the active con-
trol input(s). In either position, 
both anode and both cathode 
connectors will be active.

4. 

INPUT VOLTAGE AC METER:

 

Indicates the RMS value of AC 
input voltage.

5. 

OUTPUT AMPS METER:

 Indi-

cates output current.

6. 

OUTPUT VOLTAGE METER:

 

Indicates the value of DC output 
voltage.

7. 

DUTY CYCLE CONTROL:

 Selects 

continuous DC mode, desired 
duty cycle of standard DC 
Pulses or number of burst pulses 
for CPS modes.

8. 

VOLTAGE OUTPUT ADJUST 

CONTROL:

 Output  voltage  

from the Model VVP-15C can be 
varied from 0 Volts to Maximum 
Volts of selected Range (may be 
limited by load conditions and 
overload protection) for all out-

FRONT PANEL CONTROLS:

puts—DC, and Pulsed DC (CPS 
included).

9. 

OUTPUT FREQUENCY CON-

TROL:

 selects desired frequency 

of DC Pulses.
The Pulsed DC output from 
the unit is a rectangular pulse 
voltage with a possibility of 14 
preset duty cycles and 14 preset 
frequencies. Each duty cycle can 
be used with each frequency.
This allows for 196 standard 
pulse mode options with duty 
cycles between 10% and 80% 
and frequencies between 5 and 
120 Hz. The CPS modes have 3 
pulses per burst and 6 pulses 
per burst options that work in 
combination with designated 
frequencies (15Hz, 30Hz, 45Hz, 
60Hz, 90Hz and 120Hz) for a 

SECONDS

INPUT VOLTS AC

DUTY CYCLE

OUTPUT FREQUENCY

ON

600V

300V

OFF

VOLTAGE ADJUST

MIN.

MAX.

OUTPUT AMPS

OUTPUT VOLTS

OVERLOAD

ANODE 1

ANODE 1 & 2

OUTPUT ON

OUTPUT OFF

www.smith-root.com

Vancouver, Washington, USA

VARIABLE VOLTAGE PULSATOR

VVP

-

15C

ELECTROFISHER

50

55

45

10

60

40

20

70

35

25

15

5

80

90

120

30

 

CPS

3 PULSE

50

55

10

60

45
40

20

70

35

25

OFF

CONT. DC

80

30

4

1

2

3

5

6

7

8

9

10

11

Содержание VVP-15C

Страница 1: ...EU07955 USER S GUIDE V V P 1 5 C E L E C T R O F I S H E R...

Страница 2: ...w condition will be given credit within five days from the date of the return A return authorization must accompany returns Valid equipment returns include but are not limited to order ing incorrect e...

Страница 3: ...th less output can be used but will not achieve full output potential Recommended Generators Honda EM5000S Honda EG5000 Honda EM3800S or Honda EG3500 This equipment will not function properly when ope...

Страница 4: ...N CONTACT MAY RESULT IF PERSONNEL FAIL TO OBSERVE SAFETY PRECAUTIONS BE CAREFUL TO AVOID CONTACT WITH ALL CIRCUIT COMPONENTS AND CONNECTIONS WHILE CHECKING OR SERVICING THIS EQUIPMENT VVP 15C Combo Pa...

Страница 5: ...rom 0 Volts to Maximum Volts of selected Range may be limited by load conditions and overload protection for all out FRONT PANEL CONTROLS puts DC and Pulsed DC CPS included 9 OUTPUT FREQUENCY CON TROL...

Страница 6: ...oltage TOP BUTTON SIDE ELECTRODE CONTROL CONNECTORS 12 EMERGENCY STOP Switch disables the electrofisher For additional safety also move the input circuit breaker to the off position turn off the gener...

Страница 7: ...rgency Stop switch in the on position 4 Depress foot switch or anode pole thumb switch 5 Increase output by rotating OUTPUT ADJUST CON TROL in a clockwise move ment 6 During operation before changing...

Страница 8: ...e the following charac teristics The handle shall be con structed of a non conductive material The handle shall be of suf ficient length to avoid hand contact with the water The handle shall not be wr...

Страница 9: ...will automatically reset after three seconds The three second time out can not be bypassed Correction If average overload occurs repeatedly the operator must reduce the output voltage and or one of t...

Страница 10: ...eded Characteristics OUTPUT ON indicator and OUTPUT OFF indicator will flash alternately Output will be disabled VVP 15C will reset when safety switch is released Correction If generator overload occu...

Страница 11: ...Replace the cathode as necessary 7 Check the anode pole for cracks in the fiberglass and handle assembly Replace as necessary 8 Check the curl cord for cracks and abrasion Do not use a cracked pole o...

Страница 12: ...e proceeding 17 Never electrofish with spectators on shore Elec tric fields can travel large distances through buried pipes metal culverts and metal sheet piling If spec tators show up during elec tro...

Страница 13: ...PULSE 300 OR 600 60 CPS 3 PULSE 300 OR 600 90 CPS 3 PULSE 300 OR 600 120 CPS 3 PULSE 300 OR 600 15 CPS 6 PULSE 300 OR 600 30 CPS 6 PULSE 300 OR 600 45 CPS 6 PULSE 300 OR 600 60 CPS 6 PULSE 300 OR 600...

Страница 14: ...C ELECTRO FISHER Anode Cee Norm 1357 Control Cee Norm 13455 Cathode Cee Norm 1356 CONNECTORS ON CABLES FOR VVP 15C ELEC TROFISHER Input Power Cee Norm 21250 Anode Cee Norm 21238 Control Cee Norm 21891...

Страница 15: ...info smith root com 360 573 0202 14014 NE Salmon Creek Ave Vancouver WA 98686 www smith root com Since 1964...

Отзывы: