DESCRIPTION

The 

VARIABLE VOLTAGE PULSATOR ELECTROFISHER MODEL VVP-15C 

is 

designed to supply DC or DC Pulsed voltages for use in electrofishing.  Great care 
has been taken to improve upon the original designs of the VVP-15 and MK-22.  
This updated electrofisher provides almost identical control features and meter-
ing to allow consistency with previous samplings.  Higher efficiency is an added 
benefit of our Generation C, allowing increased samples with less wear and tear 
on equipment. 

The VVP-15C requires at minimum a 5000 watt generator to reach full rated output. 

Generators with less output can be used but will not achieve full output potential.

Recommended Generators: Honda EM5000S, Honda EG5000, Honda EM3800S or 

Honda EG3500.

This equipment will not function properly when operated from a 240 Volt AC generator if 
the generator neutral line is grounded or connected to any other points.

 Consult generator 

manufacturer for specifications regarding whether your generator has a floating neutral or 
procedures to modify your generator. This applies to both the 240Volt and 120V outputs. 
Additional caution should be taken to insure that any devices used on the 120V output are not 
internally grounded to the neutral. If the neutral connections cannot be removed a 240 volt to 
240 volt isolation transformer of adequate wattage rating must be used (5000-Watt Nominal, 
SRI line #7791).

Содержание VVP-15C

Страница 1: ...EU07955 USER S GUIDE V V P 1 5 C E L E C T R O F I S H E R...

Страница 2: ...w condition will be given credit within five days from the date of the return A return authorization must accompany returns Valid equipment returns include but are not limited to order ing incorrect e...

Страница 3: ...th less output can be used but will not achieve full output potential Recommended Generators Honda EM5000S Honda EG5000 Honda EM3800S or Honda EG3500 This equipment will not function properly when ope...

Страница 4: ...N CONTACT MAY RESULT IF PERSONNEL FAIL TO OBSERVE SAFETY PRECAUTIONS BE CAREFUL TO AVOID CONTACT WITH ALL CIRCUIT COMPONENTS AND CONNECTIONS WHILE CHECKING OR SERVICING THIS EQUIPMENT VVP 15C Combo Pa...

Страница 5: ...rom 0 Volts to Maximum Volts of selected Range may be limited by load conditions and overload protection for all out FRONT PANEL CONTROLS puts DC and Pulsed DC CPS included 9 OUTPUT FREQUENCY CON TROL...

Страница 6: ...oltage TOP BUTTON SIDE ELECTRODE CONTROL CONNECTORS 12 EMERGENCY STOP Switch disables the electrofisher For additional safety also move the input circuit breaker to the off position turn off the gener...

Страница 7: ...rgency Stop switch in the on position 4 Depress foot switch or anode pole thumb switch 5 Increase output by rotating OUTPUT ADJUST CON TROL in a clockwise move ment 6 During operation before changing...

Страница 8: ...e the following charac teristics The handle shall be con structed of a non conductive material The handle shall be of suf ficient length to avoid hand contact with the water The handle shall not be wr...

Страница 9: ...will automatically reset after three seconds The three second time out can not be bypassed Correction If average overload occurs repeatedly the operator must reduce the output voltage and or one of t...

Страница 10: ...eded Characteristics OUTPUT ON indicator and OUTPUT OFF indicator will flash alternately Output will be disabled VVP 15C will reset when safety switch is released Correction If generator overload occu...

Страница 11: ...Replace the cathode as necessary 7 Check the anode pole for cracks in the fiberglass and handle assembly Replace as necessary 8 Check the curl cord for cracks and abrasion Do not use a cracked pole o...

Страница 12: ...e proceeding 17 Never electrofish with spectators on shore Elec tric fields can travel large distances through buried pipes metal culverts and metal sheet piling If spec tators show up during elec tro...

Страница 13: ...PULSE 300 OR 600 60 CPS 3 PULSE 300 OR 600 90 CPS 3 PULSE 300 OR 600 120 CPS 3 PULSE 300 OR 600 15 CPS 6 PULSE 300 OR 600 30 CPS 6 PULSE 300 OR 600 45 CPS 6 PULSE 300 OR 600 60 CPS 6 PULSE 300 OR 600...

Страница 14: ...C ELECTRO FISHER Anode Cee Norm 1357 Control Cee Norm 13455 Cathode Cee Norm 1356 CONNECTORS ON CABLES FOR VVP 15C ELEC TROFISHER Input Power Cee Norm 21250 Anode Cee Norm 21238 Control Cee Norm 21891...

Страница 15: ...info smith root com 360 573 0202 14014 NE Salmon Creek Ave Vancouver WA 98686 www smith root com Since 1964...

Отзывы: