1.  At least one member of the 

crew must have current first 
aid and CPR cards.  

2.  Make sure every member of 

your crew knows where the 
nearest hospital is and how 
to get there or where to go 
to get help.  

3.  All members of the crew 

should have completed an 
electrofishing course.  

4.  Before loading up equip-

ment and heading into 
the field make sure every 
member of the crew knows 
your evacuation routes in 
case of an accident. 

5.  Check the equipment for 

damaged or missing parts 
and for proper operation.  
Never use an electrofisher 
that is in poor condition or 
not working correctly as it 
can present a severe shock 
hazard.

6.  Check the cathode cable 

for wear and burrs that may 
cause injury or tear holes in 
protective clothing.  Check 
the insulation for damage.  
Replace the cathode as 
necessary.  

7.  Check the anode pole for 

cracks in the fiberglass and 
handle assembly.  Replace 
as necessary.

8.  Check the curl cord for 

cracks and abrasion.  Do not 
use a cracked pole or a pole 
with a damaged curl cord.  

9.  Check your boots and high 

voltage gloves for holes.  
Boots and gloves must be 
water tight and without any 
holes.  Repair or replace as 
necessary.  

10.  If you are using chest 

waders you should use a 
wading belt.  A wading belt 
will slow the entry of water 
into the waders.  

11.  Use only dip nets with 

non-conductive handles.  
Never use an anode as a 
net, as it is extremely dan-
gerous to other members 
of the crew and can cause 
severe injury to any fish 
caught with it.  

12.  Never electrofish alone.  

13.  Never electrofish when you 

are tired.  

14.  Only one person on a crew 

can order the power for the 
electrofisher to be turned 
on, and that person is the 
crew leader.  The crew 
leader is responsible for the 
safety of everyone on the 
crew.  

SAFETY QUICK LIST

Содержание VVP-15C

Страница 1: ...EU07955 USER S GUIDE V V P 1 5 C E L E C T R O F I S H E R...

Страница 2: ...w condition will be given credit within five days from the date of the return A return authorization must accompany returns Valid equipment returns include but are not limited to order ing incorrect e...

Страница 3: ...th less output can be used but will not achieve full output potential Recommended Generators Honda EM5000S Honda EG5000 Honda EM3800S or Honda EG3500 This equipment will not function properly when ope...

Страница 4: ...N CONTACT MAY RESULT IF PERSONNEL FAIL TO OBSERVE SAFETY PRECAUTIONS BE CAREFUL TO AVOID CONTACT WITH ALL CIRCUIT COMPONENTS AND CONNECTIONS WHILE CHECKING OR SERVICING THIS EQUIPMENT VVP 15C Combo Pa...

Страница 5: ...rom 0 Volts to Maximum Volts of selected Range may be limited by load conditions and overload protection for all out FRONT PANEL CONTROLS puts DC and Pulsed DC CPS included 9 OUTPUT FREQUENCY CON TROL...

Страница 6: ...oltage TOP BUTTON SIDE ELECTRODE CONTROL CONNECTORS 12 EMERGENCY STOP Switch disables the electrofisher For additional safety also move the input circuit breaker to the off position turn off the gener...

Страница 7: ...rgency Stop switch in the on position 4 Depress foot switch or anode pole thumb switch 5 Increase output by rotating OUTPUT ADJUST CON TROL in a clockwise move ment 6 During operation before changing...

Страница 8: ...e the following charac teristics The handle shall be con structed of a non conductive material The handle shall be of suf ficient length to avoid hand contact with the water The handle shall not be wr...

Страница 9: ...will automatically reset after three seconds The three second time out can not be bypassed Correction If average overload occurs repeatedly the operator must reduce the output voltage and or one of t...

Страница 10: ...eded Characteristics OUTPUT ON indicator and OUTPUT OFF indicator will flash alternately Output will be disabled VVP 15C will reset when safety switch is released Correction If generator overload occu...

Страница 11: ...Replace the cathode as necessary 7 Check the anode pole for cracks in the fiberglass and handle assembly Replace as necessary 8 Check the curl cord for cracks and abrasion Do not use a cracked pole o...

Страница 12: ...e proceeding 17 Never electrofish with spectators on shore Elec tric fields can travel large distances through buried pipes metal culverts and metal sheet piling If spec tators show up during elec tro...

Страница 13: ...PULSE 300 OR 600 60 CPS 3 PULSE 300 OR 600 90 CPS 3 PULSE 300 OR 600 120 CPS 3 PULSE 300 OR 600 15 CPS 6 PULSE 300 OR 600 30 CPS 6 PULSE 300 OR 600 45 CPS 6 PULSE 300 OR 600 60 CPS 6 PULSE 300 OR 600...

Страница 14: ...C ELECTRO FISHER Anode Cee Norm 1357 Control Cee Norm 13455 Cathode Cee Norm 1356 CONNECTORS ON CABLES FOR VVP 15C ELEC TROFISHER Input Power Cee Norm 21250 Anode Cee Norm 21238 Control Cee Norm 21891...

Страница 15: ...info smith root com 360 573 0202 14014 NE Salmon Creek Ave Vancouver WA 98686 www smith root com Since 1964...

Отзывы: