44
According
to
the
predetermined
valgus
angle,
the
corresponding femoral valgus adapter ( «4°», «6°» or «8°» )
is inserted on the femoral reamer guide.
The femoral valgus adapter is inserted into the femoral
reamer guide, so that depending on which side is the
operation, the mark «LEFT» for left knee or «RIGHT» for right
knee is visible on the arrow «ANTER
IOR
T
»
.
The reamer bushing with the smallest diameter («Ø10») is
inserted into the femoral valgus adapter.
Important
Reamer bushings and reamers in diameter «Ø10»,
«Ø12», «Ø14», «Ø16», «Ø18» and «Ø20» are available.
Reamers are used carefully and in progressive stages
(
starting with «Ø10») with
use of the corresponding
bushing, to ream to the required stem diameter and depth.
Important
The depth indicator is on the reamer: observe the laser
markings when using this technique. The recessed notch
markings are for the IM application and are described in
the corresponding surgical technique.
When using cemented stems, the Ø 12 mm reamer is used
to drill to the desired depth. Cemented stems are available
in 80 mm, 110 mm and 150 mm lengths.
The box is prepared medially and laterally with the
oscillating saw.
Important
The medial and lateral saw cuts are aligned at an inclination
to make it easy to place the IM-guided femoral component
(valgus) in the correct position.
Preparing the femoral box
Содержание TC-PLUS Revision
Страница 2: ......
Страница 16: ...14...
Страница 58: ...58...
Страница 73: ...73...
Страница 75: ...75...
Страница 79: ...79...
Страница 81: ...81...
Страница 83: ...83...
Страница 85: ...85...
Страница 87: ...87...
Страница 88: ...88...
Страница 95: ...95 Note...
Страница 96: ...96 Note...
Страница 97: ...97 Note...