Performing a Calibration
Page 121
11.8 Recalibrating on a Point
Recalibration on a calibration point can be done if the calibration results
indicate that the participant did not focus sufficiently on an individual
calibration point.
When a calibration point has been recalibrated, the entire calibration will
then be adapted afterwards in one of the following ways:
The data from the selected point with be replaced with new data from
the recalibrated point.
The data from the previously missing point will be included in the
calibration model.
Recalibration can only be done after a calibration has
been performed, and only if no calibration settings
were changed or if another tab was selected. If another
tab was selected or if the calibration settings were
changed, the display will be turned to
Calibration Point
Setting
mode and recalibration is no longer possible.
To recalibrate on a specific calibration point:
1. Using the mouse, move over the point to be recalibrated.
2. A floating hint will appear -
Click to recalibrate
.
Содержание RED250mobile
Страница 1: ...RED250mobile System User Guide Version 4 2 1 June 2015 ...
Страница 2: ... 2015 SensoMotoric Instruments SMI RED250mobile System User Guide Page ii ...
Страница 7: ...1 Chapter Welcome ...
Страница 23: ...2 Chapter System Overview ...
Страница 34: ... 2015 SensoMotoric Instruments SMI RED250mobile System User Guide Page 28 ...
Страница 35: ...3 Chapter iViewRED Software Overview ...
Страница 55: ...4 Chapter Getting Started ...
Страница 60: ... 2015 SensoMotoric Instruments SMI RED250mobile System User Guide Page 54 ...
Страница 61: ...5 Chapter Installing iViewRED Software ...
Страница 65: ...6 Chapter Running iViewRED ...
Страница 69: ...7 Chapter Mounting the Eye Tracker ...
Страница 76: ... 2015 SensoMotoric Instruments SMI RED250mobile System User Guide Page 70 ...
Страница 77: ...8 Chapter Managing Profiles ...
Страница 83: ...9 Chapter Setting Geometry Measurements ...
Страница 93: ... 2015 SensoMotoric Instruments SMI Setting Geometry Measurements Page 87 Depth mm field ...
Страница 95: ... 2015 SensoMotoric Instruments SMI Setting Geometry Measurements Page 89 Height mm field ...
Страница 99: ...10 Chapter Positioning the Participant ...
Страница 106: ... 2015 SensoMotoric Instruments SMI RED250mobile System User Guide Page 100 ...
Страница 107: ...11 Chapter Performing a Calibration ...
Страница 129: ...12 Chapter Setting the Calibration Area ...
Страница 133: ... 2015 SensoMotoric Instruments SMI Setting the Calibration Area Page 127 ...
Страница 134: ... 2015 SensoMotoric Instruments SMI RED250mobile System User Guide Page 128 ...
Страница 135: ...13 Chapter Using Live Gaze View ...
Страница 138: ... 2015 SensoMotoric Instruments SMI RED250mobile System User Guide Page 132 ...
Страница 139: ...14 Chapter Setting the Tracking Mode ...
Страница 141: ...15 Chapter Additional Information ...
Страница 159: ...16 Chapter License Agreement and Warranty ...
Страница 168: ... 2015 SensoMotoric Instruments SMI RED250mobile System User Guide Page 162 ...
Страница 169: ...17 Chapter About SMI ...
Страница 176: ......