Operator’s Manual
HP21 Pellet Stove
~ 31 ~
WEEKLY MAINTENANCE
In addition to daily maintenance tasks, use an ash
vacuum to clean the inside of the firebox.
Remove the firepot from the pot holder and vacuum
beneath. Be sure to remove any ash from the incoming
ignitor tube.
SEE FIGURE 35
MONTHLY MAINTENANCE
In addition to daily and weekly maintenance tasks, the
lower
exhaust chambers cover plate should be removed and
vacuumed
thoroughly.
SEE FIGURE 36
This may require a hose adapter to reach inside the
chamber. This should be done monthly, or with every
2-3 tons of fuel burned.
IMPORTANT NOTE: A HOLE SHOULD BE CUT IN
THE GASKET
USING A UTILITY KNIFE TO ACCESS THE
CHAMBER. THIS
WILL ALLOW YOU TO REUSE THE
GASKET
BI-MONTHLY (OR EVERY 2-3 TONS OF
FUEL)
Remove and clean the exhaust venting.
Remove and clean the combustion motor, housing and
impellers.
SEE FIGURE 37
Figure 35
Figure 36: Remove lower exhaust chamber
’
s cover plate and clean
Figure 37: Remove combustion motor and clean