Smeg WO-20 Скачать руководство пользователя страница 23

 

 
7596040 – MANUALE WO-20 EN 21052018 REV.1 
 

 

   - 23 - 

 

ANNEX III – MAINTENANCE LOG 

INSTALLATION 

TECHNICIAN 

DATE 

SIGNATURE 

 
 

 

 

ORDINARY MAINTENANCE 

TECHNICIAN 

DATE 

SIGNATURE 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 

Содержание WO-20

Страница 1: ...WO 20 Potable water treatment osmosis system for HO RE CA applications MANUAL use and maintenance...

Страница 2: ...ar 2018 and subsequent 5 The object of the declaration described above is in conformity with the relevant Union harmonization legislation 2006 42 EU machines 2014 30 EU EMC 2014 35 EU LVD 2011 65 EU R...

Страница 3: ...9 3 2 EXCHANGE OF DRAIN CAPILLARY 10 4 FUNCTIONING 11 4 1 FIRST START UP 11 4 2 NORMAL USE 11 4 3 MIX BY PASS 11 4 5 LOW PRESSURE ALARM 11 4 6 LEACKAGE ALARM 11 4 7 INACTIVITY 11 4 8 ELECTRONIC BOARD...

Страница 4: ...own researches and spare parts requests please contact the manufacturer or a qualified service centre Read carefully the instructions for installation operation and maintenance before installing this...

Страница 5: ...bed in this manual and they have not to perform tasks reserved to maintenance or qualified technician WARNING All extraordinary maintenance operations must be done by qualified personnel only 1 4 CARE...

Страница 6: ...bsence of periodic maintenance IT IS STRICTLY FORBIDDEN to use the equipment in hygienic conditions or environments that aren t in compliance with those indicated in this manual IT IS STRICTLY FORBIDD...

Страница 7: ...OGIC From the water inlet the water first goes through a prefiltration system to protect the membrane and put under pressure by the pump is presurated in the vessel containing the membrane The permeat...

Страница 8: ...nic board F3 15A PERMEATE WATER SPECIFICATIONS Output maximum flow rate c a 120 Recovery percentage Vedi 3 2 WARNING The percentage of dissolved salts and other rejected elements is influenced by the...

Страница 9: ...siphon Use new compliant washing tubes in compliance with EN61770 with diameter no less than DN10 Do not reuse old or worn pipes CHECKS TO DO BEFORE INSTALLATION Presence and efficiency of the ground...

Страница 10: ...ater 1200 mS or 35 dH Maximum recovery rates refer to incoming water at 25 F pH 8 5 9 5 BLACK 55h WHITE 50h SOFTENER NEEDED 7 5 8 5 BLUE 60h WHITE 50h 60h 6 5 7 5 BLACK 55h WHITE 50h 0 6 F 6 15 F 15 2...

Страница 11: ...nd it mixes it with the permeated water downstream of the membranes The device must be calibrated in the installation phase With WO 20 treated water retains about 10 15 of the original saline In the e...

Страница 12: ...ton the software release is displayed It performs the flushing of the membranes for 2 minutes by opening the inlet solenoid valve It resets the hours of operation of the filter Confirm with It display...

Страница 13: ...th the and buttons and confirm with the Select functioning by time or without time limit with the and buttons and confirm with the button Access the modification of the litres hour conversion paramete...

Страница 14: ...ilter capacity has not been reached 5 1 TASKS OF MAINTENANCE PERSONNEL The ordinary maintenance plan described in this paragraph must be done according to the time indicated to keep the machine functi...

Страница 15: ...original spare parts This maintenance must be documented in the appropriate space in the maintenance log see Annex III It is advisable to carry out an extraordinary maintenance at least once every 6...

Страница 16: ...ut forcing it in any way making sure to enter the tabs in their own seats in the head and turn it 90 to the right until it stops without forcing fig d To facilitate the entrance you can moisten slight...

Страница 17: ...the cover fig f At the rear of the machine find the inflation valve of the expansion tank fig g With a manometer check that the indicated pressure is 0 1 MPa If necessary restore it with a compressor...

Страница 18: ...ogen peroxide at 10 volumes per 10 liters of osmotic water or dose 100 ml of hydrogen peroxide at 24 volumes per 10 liters of osmotic water Insert the sanitizing cartridge s and close the conditioning...

Страница 19: ...ected Check the flat connection cable of the display to the board fasten it properly Defective display Replace the display Defective board Replace the board Problem Intervention of the fuse and protec...

Страница 20: ...stening of cable that goes to terminals Problem The machine produces little water Cause Solution Clogged solenoid valve Check the input solenoid valve status and operation if it is clogged replace it...

Страница 21: ...pment must be delivered to an WEEE waste center CER 20 01 36 WASTE OF ELECTRICAL ELECTRONIC EQUIPMENT UK EU directive 2002 96 EC classifies this product as an electrical or electronic tool Do Not disp...

Страница 22: ...UCTIVITY PROBE 2 1 1 1 Scala Scale Denominazione Product name Progettista Designer Verifica Confirm Codice prodotto Product code Applicazione Application N disegno N drawing Esecutivo Executive Sperim...

Страница 23: ...7596040 MANUALE WO 20 EN 21052018 REV 1 23 ANNEX III MAINTENANCE LOG INSTALLATION TECHNICIAN DATE SIGNATURE ORDINARY MAINTENANCE TECHNICIAN DATE SIGNATURE...

Страница 24: ...7596040 MANUALE WO 20 EN 21052018 REV 1 24...

Отзывы: