User Manual
WD2145-WD1160-WD4060-WD4190
Page 62 - 85
ALARM ID
DESCRIPTION
USER ACTION
A-:68
P1 jerry can empty
Check that there is detergent in the jerry can
or that the level
sensor is operating correctly.
This is a warning and not an alarm as such; the washing cycle can
be started with this message present (i.e. overriding the warning)
by pressing the
Start/Stop
button again (hold it down for 2
seconds).
Activated at the end of the cycle and when the user attempts to
start a new program. If two or more similar alarms (e.g. cans P1
and P2 empty), the
Start/Stop
button will have to be pressed
twice or more before the cycle can be started. (The device’s
internal memory records the event but allows execution of the
cycle).
A-:69
P2 jerry can empty
As for “A-:68”
A-:70
P3 jerry can empty
As for “A-:68”
AF:73
Internal memory data storage
error
For the user: follow the
DEFAULT PROCEDURE
described above.
If the alarm does not disappear, follow the
RESET PROCEDURE.
AF:74
Water leak from chamber. Alarm
only enabled with the Aquastop
accessory fitted.
Turn off the water supply taps.
Contact the After-Sales Service.
AF:75
No salt in softener. This alarm
does not appear on the Display but
is recorded in the appliance
memory; the relative LED
illuminates on the display.
Add salt to the softener salt tank inside the chamber, accessible
with the door open.
AF:77
Intake water temperature over
45°C; prewash temperature must
be below 45°C. (Alarm generally
disabled on GW series products.)
The alarm occurs when the temperature is over 45°C at the start
of the cycle.
Wait for the appliance to cool before starting a new cycle.
AF:78
Restore fail
. Problem of
motherboard.
For the user: follow the
DEFAULT PROCEDURE
described above.
If the alarm does not disappear, follow the
RESET PROCEDURE.
AF:79
Program not compatible.
This alarm is triggered if a program is created using the
TRACELOG software using procedures not compatible for the
proper performance of the cycle. Reconsider the program
created phase by phase; it may be useful to compare it with an
original program provided as reference (see attached
PROGRAMS TABLE doc.).
Pay special attention to the version of the appliance being used;
e.g. do not activate peristaltic pump P3 when writing the
program if this pump is not installed.
AF:84
Dryer temperature reading higher
than actual temperature. (only for
WD4060, WD4190 series)
Wait for the alarm to be resolved automatically.
During automatic management of the AF:84 alarm the RESET
cycle cannot be started.
Do not disconnect the electricity supply to the device: the
overheating problem is being dealt with automatically, with a
heating element cooling cycle.
The
DEFAULT PROCEDURE
described above cannot be
implemented until the end of the automatic process.
AF:91
Internal memory full.
This alarm only occurs if the appliance parameter that prevents
overwriting in the memory is enabled.
With the default setting, this alarm will not occur.
Memory space must be cleared to allow use of the appliance to
continue: this can be done by connecting to the appliance by
means of the
RS-232
serial port and using the
TRACELOG
software.