Installation
103
EN
The nozzles not provided are available at Authorised Service Centres.
5 LPG G30/31
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.8
3.0
4.0
Nozzle diameter (1/100 mm)
50
65
85
100
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced flow rate (W)
400
500
800
1300
Rated flow rate G30 (g/h)
73
131
218
291
Rated flow rate G31 (g/h)
71
129
214
286
6 LPG G30/31
AUX
SR
R
UR2
Rated heating capacity (kW)
1.1
1.9
3.0
4.2
Nozzle diameter (1/100 mm)
50
65
81
95
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced flow rate (W)
450
550
900
1500
Rated flow rate G30 (g/h)
80
138
218
305
Rated flow rate G31 (g/h)
79
136
214
300
7 LPG G30/31
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.8
3.0
4.1
Nozzle diameter (1/100 mm)
43
58
74
80
Pre-chamber (printed on nozzle)
(H2)
(M)
(Z)
(F4)
Reduced flow rate (W)
400
500
1000
1500
Rated flow rate G30 (g/h)
73
131
218
298
Rated flow rate G31 (g/h)
71
129
214
293
8 Town gas G110
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.75
2.8
3.3
Nozzle diameter (1/100 mm)
145
185
260
340
Pre-chamber (printed on nozzle)
/8
/2
/3
0190
Reduced flow rate (W)
400
500
800
1000