4. USING THE HOB

Before turning on the burners, make sure that the burners, flame-spreader
crowns and racks are fitted correctly. 
In the ultra-rapid burner, notch 

A

 must be aligned with pin 

B

.

4.1

Lighting the burners

The    burner    controlled    by    each    knob    is    shown    next    to    the    knob.  The
appliance is equipped with electronic ignition. Simply press the knob and
simultaneously turn it anticlockwise to the minimum flame symbol, until it lights.
On valved models, hold down the knob for about 2 seconds to keep the flame lit
and to activate the safety device. The burner may go out when the knob is
released. If this happens, repeat the procedure, holding the knob down for
longer.

(On some models only)

Double-crown burners comprise an
auxiliary and a rapid burner, controlled by
two different knobs which permit to use
both burners at the same time or to select
one or the other as required.

If the burners should go out accidentally, after about 20 seconds a safety device
will be tripped, cutting off the gas supply, even if the gas tap is open.

Содержание SR775AOD

Страница 1: ...cleaning and maintenance of the appliance INSTRUCTIONS FOR THE INSTALLER these are intended for the qualified technician who must install the appliance set it functioning and carry out an inspection t...

Страница 2: ...OTHER THAN AS INDICATED IF THE APPLIANCE IS INSTALLED ON BOATS OR IN CARAVANS DO NOT USE IT AS A ROOM HEATER DO NOT USE THIS APPLIANCE FOR HEATING ROOMS THIS APPLIANCE IS MARKED ACCORDING TO EUROPEAN...

Страница 3: ...T THE CONTROL KNOBS ARE IN THE OFF POSITION WHEN YOU FINISH USING THE HOB NEVER PLACE PANS WITH BOTTOMS WHICH ARE NOT PERFECTLY FLAT AND SMOOTH ON THE COOKING HOB RACKS NEVER USE CONTAINERS WHICH PROJ...

Страница 4: ...FORE CARRYING OUT INSTALLATION MAINTENANCE WORK MAKE SURE THAT THE APPLIANCE IS NOT CONNECTED TO THE POWER GRID THE PLUG TO BE CONNECTED TO THE POWER SUPPLY CABLE AND ITS SOCKET MUST BE OF THE SAME TY...

Страница 5: ...COULD REACH THE ELECTRONICS DAMAGING THEM AND CAUSING SHORT CIRCUITS DO NOT MODIFY THIS APPLIANCE DO NOT SPRAY ANY SPRAY PRODUCTS NEAR THE ELECTRICAL APPLIANCE WHILE IT IS IN OPERATION DO NOT USE SPR...

Страница 6: ...r results in the application of administrative sanctions The product does not contain substances in quantities sufficient to be considered hazardous to health and the environment in accordance with cu...

Страница 7: ...nimum flame symbol until it lights On valved models hold down the knob for about 2 seconds to keep the flame lit and to activate the safety device The burner may go out when the knob is released If th...

Страница 8: ...1 Auxiliary 7 18 2 Semi rapid 10 24 3 Medium Rapid 12 24 4 Large Rapid 14 26 5 Double crown ultra rapid 12 28 6 Triple crown ultra rapid 22 28 7 Fish burner Suitable oval containers For burner referen...

Страница 9: ...ry daily cleaning To clean and preserve surfaces always use only specific products that do not contain abrasives or chlorine based acids How to use pour the product onto a damp cloth and wipe the surf...

Страница 10: ...ese components must not be washed in the dishwasher 5 2 3 Flame spreader crowns The flame spreader crowns are removable Wash them with hot water and non abrasive detergent making sure to remove any en...

Страница 11: ...he cooktop remove the lid unit by lifting it upwards When finished cleaning refit the cover making sure to insert it correctly Before lifting up the lid dry out any liquid that may have dripped Never...

Страница 12: ...that a distance of 145 mm be kept between the appliance and the wall as shown in the figure so as to avoid damage from overheating Make sure that there is a minimum distance of 750 mm between the stov...

Страница 13: ...an empty kitchen unit with doors a separation panel must be placed under the hob Keep a minimum distance of 10 mm between the bottom of the hob and the surface of the panel which must be easily extrac...

Страница 14: ...equal to or greater than 3 mm in an easily accessible position close to the appliance Avoid use of adapters and shunts If the power cable is replaced the cross section of wires in the new cable must b...

Страница 15: ...as G20 2H G20 G25 2E at a pressure of 20 mbar 20 25 mbar For supplying it with other types of gas see chapter 9 ADAPTATION TO DIFFERENT TYPES OF GAS The gas inlet connection is threaded external gas I...

Страница 16: ...protected by grills must be the right size to comply with current regulations and positioned so that no part of them is obstructed not even partially The room must be kept adequately ventilated in ord...

Страница 17: ...es must be replaced and the primary air must be adjusted In order to replace the nozzles and adjust the burners the hob top must be removed as described below 9 1 Removing the hob top 1 Remove all the...

Страница 18: ...icated in the chart in paragraph 5 5 Primary air adjustment and then secure the tube by means of screw A After the adjustments have been carried out restore the seals with sealing wax or equivalent ma...

Страница 19: ...natural gas The cooker hob is preset for natural gas G25 2ELL at a pressure of 20 mbar To reset the appliance for operation with this type of gas carry out the same steps as described in 9 2 Adjustmen...

Страница 20: ...25 mbar G20 20 mbar Nozzle diameter 1 100 mm Reduced capacity W Auxiliary 1 1 05 73 380 Semi rapid 2 1 65 92 380 Medium rapid 3 2 55 115 650 Large Rapid 4 3 1 126 750 Ultra rapid 5 3 3 130 1200 Double...

Страница 21: ...til the correct minimum flame is achieved Refit the knob and verify that the burner flame is stable when turning the knob rapidly from the maximum to the minimum position the flame must not go out 9 6...

Страница 22: ...d 3 Medium Rapid 4 Large Rapid 5 Triple crown ultra rapid 6 Double crown ultra rapid 7 Fish burner 9 8 Lubrication of gas taps Over time the gas taps may become difficult to turn and get blocked Clean...