background image

 

 

 

 

 

EN 

1

10 

USE

 

 
 
 
 

Control panel 

Button Function 

Led 

Turns the lighting system on and off at maximum in-
tensity. 

On/Off 

 

Press and hold for 2 seconds to turn the lighting system 
on and off at reduced intensity. 

On/Off 

Turns the Motor off. 

 

 

Press and hold for approximately 5 seconds to Lock / 
Unlock the Keyboard, for example in order to clean the 
surface. 

The buttons turn light up one at a time in cycle. 

Turns the Motor on at Speed one. 

On/Off 

Turns the Motor on at Speed two. 

On/Off 

Turns the Motor on at Speed three. 

On/Off 

Activates/Deactivates 

intensive

 speed from any other 

speed, including motor off. This speed is set to operate 
for 10 minutes, after which the system returns to the 
speed that was set before. Suitable to deal with 
maximum levels of cooking fumes. Can also be 
deactivated by pressing button 

B

Flashes once a second. 

 

Press and  hold the button for approximately 5 seconds, 
with all the loads turned off (Motor and Lights), to turn 
the Activated Charcoal Filter alarm on/off.  

Button G

 (Flashes twice)-Alarm Activated. 

Button G

 (Flashes once)-Alarm Deactivated. 

24H function 

Starts the Motor at a speed that allows suction of 100 
m3/h for 10 minutes per hour for 24h, after which the 
Motor will stop. It cannot be activated if the 

Intensive

 

or 

Delay

 functions are in use. 

On/Off 

 

When the filters alarm is triggered, the alarm can be 
reset by pressing and holding this button for 
approximately 5 seconds.  
These indications are only visible when the motor is 
turned off.

 

B

 flashes two times. 

 
When the procedure terminates, the indication shown 
previously turns off: 

Button G flashes

, indicating the need to wash the metal 

grease filters. The alarm is triggered after the Hood has 
been in operation for 100 working hours.  

Button G flashes

, indicating the need to change the 

activated charcoal filters, and also to wash the metal grease 
filters. The alarm is triggered after the Hood has been in 
operation for 200 working hours. 

Delay function 

 

Activates/Deactivates automatic switch-off with a 30’ 
delay. Suitable to complete elimination of residual 
odours. Can be activated from any position. It cannot 
be activated if the 

Intensive

 or 

24H

 functions are in 

use. 

On/Off 

 

Press and hold the button for approximately 5 seconds, 
with all the loads turned off (Motor and Lights), to turn 
the Remote control on/off.  

Button B

 (Flashes twice)-Remote control Activated. 

Button B

 (Flashes once)-Remote control Deactivated. 

Remote control receiver. 

 

 

Содержание SHW1235X

Страница 1: ...Instructions Manual SHW935X SHW1235X ...

Страница 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 6 USE 10 MAINTENANCE 11 EN ...

Страница 3: ...ks WARNING Failuretoinstallthescrewsorfixingdeviceinaccordancewiththeseinstructionsmay resultinelectricalhazards USE Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells Neverusethehoodforpurposesotherthanforwhichithasbeendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation Adjust the flame intensity to direct it onto the bottom of the pan only making sure ...

Страница 4: ...3 1 Motor unit 8 1 Directional Grille ø 125 mm 9 1 Reduction Flange ø 150 120 mm 10 1 Dumper ø150 mm 19 1 Cable raceway Ref Q ty Installation Components 7 2 1 2 Upper chimney fixing brackets 11 6 Plugs 12a 6 Screws 4 2 x 44 4 12c 6 Screws 2 9 x 9 5 12e 2 Screws 2 9 x 9 5 12f 6 Screws 3 5 x 9 5 Q ty Documentation 1 Instruction Manual 2 1 2 2 2 12c 12a 7 2 1 11 11 12a 9 12e 8 1 3 12f 19 10 ...

Страница 5: ...EN 5 5 Dimensions Min 650mm Min 650mm ...

Страница 6: ...2f to fix it in the position shown in the figure locking the Hood wiring in place Make the electrical connections between the Motor Unit 3 and the Hood Canopy 1 connecting the Controls connector and the Lighting connector Warning Make sure that the Connectors are properly inserted into the housing Warning There will be a specific Connector according to the type of controls For the Recirculation Ve...

Страница 7: ... centre grooves with the vertical reference line Warning The Bracket must be in a position that allows a minimum distance of 50mm from the upper part of the Motor unit so if when measured the position of the Bracket is found to be below the Motor unit the bracket must be fitted 50 mm above this Mark the centres of the holes in the bracket As shown in the drawing mark a reference point 116 mm from ...

Страница 8: ... clamps not sup plied To install a ø 120 pipe To install a ø 120 mm air exhaust connection insert the re ducer flange 9 on the dumper 10 Fix the pipe in position using sufficient pipe clamps not sup plied Remove any activated charcoal filters 9 ø120 ø150 10 10 RECIRCULATION VERSION AIR OUTLET Cut a hole ø 125 mm in any shelf that may be positioned over the hood Insert the reducer flange 9 on the h...

Страница 9: ...er again until they are in contact Fix the upper part of the Chimney to the upper Bracket at the side using the Screws 12c 2 9 x 9 5 provided Warning If it has been extended so far that the lower slots in the upper chimney are level with the holes in the bracket use the screws 12c provided to fix it otherwise only use the bottom bracket as a stop for the upper chimney Lower chimney Open out the tw...

Страница 10: ...d that allows suction of 100 m3 h for 10 minutes per hour for 24h after which the Motor will stop It cannot be activated if the Intensive or Delay functions are in use On Off When the filters alarm is triggered the alarm can be reset by pressing and holding this button for approximately 5 seconds These indications are only visible when the motor is turned off B flashes two times When the procedure...

Страница 11: ...on G flashes or at least once every 2 months use or more frequently if use is particularly intensive Resetting the alarm signal Turn the Lights and the Suction motor off then disable the 24h function if enabled Press button G and hold for approximately 5 seconds See paragraph on Use Cleaning the Filters Remove the filters one at a time holding them up with one hand and pulling the handle downwards...

Страница 12: ...tor off Press F and hold for approximately 5 seconds Button G flashes twice A C Filter saturation alarm ACTIVATED Button G flashes once A C Filter saturation alarm DEACTIVATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Turn the Lights and the Suction Motor off Press button G and hold for approximately 5 seconds See paragraph on Use Changing the Filter Remove the Metal grease...

Страница 13: ...are completely dry Replace the Activated charcoal filters Replace the Metal grease filters and the Suction Panel Warning Take care not to damage break the element when it is being removed replaced Lighting unit Warning This appliance is fitted with a white LED lamp classed as 1M according to EN 60825 1 1994 A1 2002 A2 2001 standards maxi mum optical power emitted 439nm 7µW Do not look directly at ...

Страница 14: ......

Страница 15: ......

Страница 16: ...436006024_ver2 ...

Отзывы: