RECOMMENDATIONS AND SUGGESTIONS

 

  The Instructions for Use apply to several versions of this appliance. Accordingly, you may find 

descriptions of individual features that do not apply to your specific appliance. 

INSTALLATION 

•  The manufacturer will not be held liable for any damages resulting from incorrect or improper 

installation. 

•  The minimum safety distance between the cooker top and the extractor hood is 650 mm (some 

models can be installed at a lower height, please refer to the paragraphs on working dimensions 

and installation). 

•  Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of 

the hood. 

•  For Class I appliances, check that the domestic power supply guarantees adequate earthing. 

  Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route 

of the flue must be as short as possible. 

•  Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, 

etc.). 

•  If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a 

sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of 

exhaust gas. The kitchen must have an opening communicating directly with the open air in order 

to guarantee the entry of clean air. When the cooker hood is used in conjunction with appliances 

supplied with energy other than electric, the negative pressure in the room must not exceed 0,04 

mbar to prevent fumes being drawn back into the room by the cooker hood. 

•  In the event of damage to the power cable, it must be replaced by the manufacturer or by the 

technical service department, in order to prevent any risks.  

  “WARNING: Failure to install the screws or fixing device in accordance with these instructions may 

result in electrical hazards.” 

USE 

•  The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells. 

•  Never use the hood for purposes other than for which it has been designed. 

•  Never leave high naked flames under the hood when it is in operation. 

•  Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not 

engulf the sides. 

•  Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. 

•  Do not flambè under the range hood; risk of fire  

•  This appliance is not intended for use by persons (including children) with reduced physical, sen-

sory or mental capabilities, or lack of experience and knowledge, unless they have been given su-

pervision or instruction concerning use of the appliance by a person responsible for their safety. 

•  Children should be supervised to ensure that they do not play with the appliance. 

• “WARNING: Accessible parts may become hot when used with cooking appliances.”. 

MAINTENANCE 

•  Switch off or unplug the appliance from the mains supply before carrying out any maintenance 

work. 

•  Clean and/or replace the Filters after the specified time period (Fire hazard). 

•  Clean the hood using a damp cloth and a neutral liquid detergent. 

 

The symbol 

 on the product or on its packaging indicates that this product may not be treated as household waste. Instead it 

shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product 
is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could 
otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, 
please contact your local city office, your household waste disposal service or the shop where you purchased the product. 

 

 

Содержание SHW1235X

Страница 1: ...Instructions Manual SHW935X SHW1235X ...

Страница 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 6 USE 10 MAINTENANCE 11 EN ...

Страница 3: ...ks WARNING Failuretoinstallthescrewsorfixingdeviceinaccordancewiththeseinstructionsmay resultinelectricalhazards USE Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchensmells Neverusethehoodforpurposesotherthanforwhichithasbeendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation Adjust the flame intensity to direct it onto the bottom of the pan only making sure ...

Страница 4: ...3 1 Motor unit 8 1 Directional Grille ø 125 mm 9 1 Reduction Flange ø 150 120 mm 10 1 Dumper ø150 mm 19 1 Cable raceway Ref Q ty Installation Components 7 2 1 2 Upper chimney fixing brackets 11 6 Plugs 12a 6 Screws 4 2 x 44 4 12c 6 Screws 2 9 x 9 5 12e 2 Screws 2 9 x 9 5 12f 6 Screws 3 5 x 9 5 Q ty Documentation 1 Instruction Manual 2 1 2 2 2 12c 12a 7 2 1 11 11 12a 9 12e 8 1 3 12f 19 10 ...

Страница 5: ...EN 5 5 Dimensions Min 650mm Min 650mm ...

Страница 6: ...2f to fix it in the position shown in the figure locking the Hood wiring in place Make the electrical connections between the Motor Unit 3 and the Hood Canopy 1 connecting the Controls connector and the Lighting connector Warning Make sure that the Connectors are properly inserted into the housing Warning There will be a specific Connector according to the type of controls For the Recirculation Ve...

Страница 7: ... centre grooves with the vertical reference line Warning The Bracket must be in a position that allows a minimum distance of 50mm from the upper part of the Motor unit so if when measured the position of the Bracket is found to be below the Motor unit the bracket must be fitted 50 mm above this Mark the centres of the holes in the bracket As shown in the drawing mark a reference point 116 mm from ...

Страница 8: ... clamps not sup plied To install a ø 120 pipe To install a ø 120 mm air exhaust connection insert the re ducer flange 9 on the dumper 10 Fix the pipe in position using sufficient pipe clamps not sup plied Remove any activated charcoal filters 9 ø120 ø150 10 10 RECIRCULATION VERSION AIR OUTLET Cut a hole ø 125 mm in any shelf that may be positioned over the hood Insert the reducer flange 9 on the h...

Страница 9: ...er again until they are in contact Fix the upper part of the Chimney to the upper Bracket at the side using the Screws 12c 2 9 x 9 5 provided Warning If it has been extended so far that the lower slots in the upper chimney are level with the holes in the bracket use the screws 12c provided to fix it otherwise only use the bottom bracket as a stop for the upper chimney Lower chimney Open out the tw...

Страница 10: ...d that allows suction of 100 m3 h for 10 minutes per hour for 24h after which the Motor will stop It cannot be activated if the Intensive or Delay functions are in use On Off When the filters alarm is triggered the alarm can be reset by pressing and holding this button for approximately 5 seconds These indications are only visible when the motor is turned off B flashes two times When the procedure...

Страница 11: ...on G flashes or at least once every 2 months use or more frequently if use is particularly intensive Resetting the alarm signal Turn the Lights and the Suction motor off then disable the 24h function if enabled Press button G and hold for approximately 5 seconds See paragraph on Use Cleaning the Filters Remove the filters one at a time holding them up with one hand and pulling the handle downwards...

Страница 12: ...tor off Press F and hold for approximately 5 seconds Button G flashes twice A C Filter saturation alarm ACTIVATED Button G flashes once A C Filter saturation alarm DEACTIVATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Turn the Lights and the Suction Motor off Press button G and hold for approximately 5 seconds See paragraph on Use Changing the Filter Remove the Metal grease...

Страница 13: ...are completely dry Replace the Activated charcoal filters Replace the Metal grease filters and the Suction Panel Warning Take care not to damage break the element when it is being removed replaced Lighting unit Warning This appliance is fitted with a white LED lamp classed as 1M according to EN 60825 1 1994 A1 2002 A2 2001 standards maxi mum optical power emitted 439nm 7µW Do not look directly at ...

Страница 14: ......

Страница 15: ......

Страница 16: ...436006024_ver2 ...