Name
W
21
Grill
2400
TYPE AND SECTION OF POWER CABLES
2400 W
3 X 1.5 mm
2
(*)
2400 W
3 X 1.5 mm
2
(*)
ELECTRICAL COMPONENTS OUTPUT
MAINTENANCE
Before carrying out maintenance of any kind,
disconnect the appliance from the mains. All
maintenance must be carried out by authorized
personnel only.
6) PART REPLACEMENT
To replace components located inside the barbecue
the resistance should be lifted up and secured in
the vertical position. Take out the drip pan
containing the lava stone and loosen the four
screws that are under it (see fig. 8). The work
surface can now be detached from the worktop
giving access to all internal components.
To reassemble the work surface of the appliance
take care not to damage the power cables and
make certain that they are well positioned in the
guides along the side of the appliance.
Note: In the event the power cord is replaced,
the ground wire must be left longer than the
lead wires (fig. 9) and the instructions in the
paragraph "ELECTRICAL CONNECTIONS" must
be observed.
To reassemble the appliance repeat the steps
above in the reverse order.
7) TECHNICAL SPECIFICATIONS OF
ELECTRICAL COMPONENTS
To facilitate the task of the installer a table with
component specifications is included below.
Type
Total output of
Single-phase power supply
of cable
appliance
230 – 240 V ~
Rubber
H05 RR-F
Neoprene
H05 RN-F
FIG. 8
FIG. 9