Instructions for the installer
5.
ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, unplug the
appliance from the electric socket.
The cooktop has been inspected for LPG gas G30/G31 (3+) at a
pressure of 28/37 mbar. For functioning with other types of gas the
nozzles must be replaced and the primary air adjusted.
To replace the nozzles and regulate the burners, you have to remove the
top as described in the following paragraph.
5.1
Removing the cooktop
1.
Remove all the knobs, the grates, the burner caps and the burner
rings;
2.
remove the screws and the nuts
A
holding the burner supports;
3.
remove plates
B
;
4.
lift the cooktop from its seat;
5.
replace the burner nozzles in accordance with the reference gas
chart;
6.
regulate the primary air as described in paragraph “5.2 Regulation
for LPG”.
11