37
Electrical
connection
Make sure that the mains electricity supply in the home
is of the voltage and power indicated on the date plate
underneath the hob.
The power supply lead is not supplied.
Use a cable of type H05RRF or H05RNF, bearing in
mind that the earth wire (yellow-green) must be about
20 mm. Longer at the end for connection to the
appliance. Make sure that the lead is not in contact with
heated zones.
On installation, provide an omnipolar circuit breaker
with minimum distance between contacts at least 3 mm
on the appliance power supply line, at a point easily
reached from the appliance.
The options for connection to the electrical mains are
indicated in the tables below or on the data plate
underneath the hob.
Cables H 05 RRF - H 05 RNF
230V~
400V 3N~
400V 2N~
Minimum gauge in mm
2
2,5
1,5
2,5
To access the terminal board press the
two
side tabs as
indicated on the terminal board cover.
Modify the arrangement of the jumpers on the terminal
board if necessary, then fix the wires, making sure that
the earth wire is about 20 mm longer.
Fix the power supply lead to the terminal and pass it
through the hole in the lid.
Содержание SE 2741
Страница 2: ...Pagina 1 15 Page 17 31 Page 33 47 Seite 49 63 Página 65 79 Bladzijde 81 95 ...