Installation
39
EN
Connection to LPG
Use a pressure regulator and make the
connection on the gas cylinder following
the guidelines set out in the standards in
force.
The supply pressure must comply with the
values indicated in the table “Burner and
nozzle characteristics tables”.
Connection with a steel hose with conical
fitting
Make the connection to the gas mains
using a continuous wall steel hose whose
specifications comply with the applicable
standard.
Carefully screw the hose connector
3
to the
appliance’s gas connector
1
(½” thread
ISO 228-1), placing the supplied seal
2
between them. Apply insulating material to
the thread of connector
3
, then tighten the
steel hose
4
to the connector
3
.
Room ventilation
The appliance should be installed in rooms
that have a permanent air supply in
accordance with the standards in force. The
room where the appliance is installed must
have enough air flow for the regular
combustion of gas and the necessary air
change in the room itself. The air vents,
protected by grilles, must be the right size to
comply with current regulations and
positioned so that no part of them is
obstructed, not even partially.
The room must be kept adequately
ventilated in order to eliminate the heat and
humidity produced by cooking: In
particular, after prolonged use, you are
recommended to open a window or to
increase the speed of any fans.
Extraction of the combustion products
The combustion products may be extracted
by means of hoods connected to a natural
draught chimney whose efficiency is certain
or via forced extraction. An efficient
extraction system requires precision
planning by a specialist qualified in this
area and must comply with the positions
and clearances indicated by the applicable
standards.
When the job is complete, the installer must
issue a certificate of conformity.
This appliance is not connected to
an exhaust system for combustion
products. It must be installed and
connected in compliance with the
current installation regulations.
Special attention should be paid to
the relevant requirements as for
ventilation.