Installation
51
EN
Burner and nozzle characteristics tables
1
Natural Gas G20 – 20 mbar
AUX
SR
RR
R
UR
Rated heating capacity (kW)
1.0
1.6
2.4
2.8
3.5
Nozzle diameter (1/100 mm)
67
87
107
118
135
Reduced flow rate (W)
400
500
900
900
1100
Primary air (mm)
8
1
1
1
1
Marking on nozzle
S1
S1
-
-
-
2
Natural Gas G25 – 25 mbar
AUX
SR
RR
R
UR
Rated heating capacity (kW)
1.0
1.6
2.5
2.9
3.5
Nozzle diameter (1/100 mm)
77
90
114
128
133
Reduced flow rate (W)
400
500
900
900
1100
Primary air (mm)
4
4
4
4
4
Marking on nozzle
C
B
B
B
B
3
Natural Gas G25 – 20 mbar
AUX
SR
RR
R
UR
Rated heating capacity (kW)
1.0
1.6
2.4
2.9
3.5
Nozzle diameter (1/100 mm)
75
94
115
128
138
Reduced flow rate (W)
400
500
900
900
1100
Primary air (mm)
10
10
2
2
2
Marking on nozzle
F4
X
S
S
S
4
LPG G30/31 - 30/37 mbar
AUX
SR
RR
R
UR
Rated heating capacity (kW)
0.9
1.6
2.5
2.9
3.5
Nozzle diameter (1/100 mm)
48
62
76
81
90
Reduced flow rate (W)
400
500
900
900
1100
Primary air (mm)
10
10
10
10
10
Marking on nozzle
-
-
-
-
-
Rated flow rate G30 (g/h)
65
116
182
218
254
Rated flow rate G31 (g/h)
64
114
179
214
250
5
LPG G30/G31 - 50 mbar
AUX
SR
RR
R
UR
Rated heating capacity (kW)
1.0
1.6
2.5
2.9
3.5
Nozzle diameter (1/100 mm)
42
54
65
72
80
Reduced flow rate (W)
500
600
1000
1000
1400
Primary air (mm)
OPEN
4
4
4
4
Marking on nozzle
-
-
-
-
-
Rated flow rate G30 (g/h)
73
116
182
218
254
Rated flow rate G31 (g/h)
71
114
179
214
250
Содержание PVL675LCN