background image

Conversion Kit

8

7)

Refit the crowns, flame caps and grids on the cooktop in the following
order:

1 Fit the crowns, ensuring that they are perfectly locked into their

housing on the cooktop.

2 Fit the flame caps on the crowns, ensuring that the edges match

perfectly.

3 Fit the grids, making sure to fasten the side spokes in the special

A” seats found on the cooktop.

These procedures must be repeated for each burner on the cooktop.

Caution: refit all flame caps in the same points from which they were removed. In fact, it is not possible to
change the flame cap positions. After refitting them, ensure that they are perfectly in place and that there
is no clearance between the cooktop and the flame caps.

8)

Complete steps 3, 5 and 6 for each burner on the cooktop.

  WARNING

FIRE HAZARD

-  Use a soapy solution to check for proper tightness.

-  Never test for gas leaks with a match or other flames.

-  Failure to follow this instruction can result in death or fire

9)

Leak testing of the appliance must be conducted according to the following instructions:
Use a brush and liquid detergent to test all gas connections for leaks. Bubbles around connections
indicate a leak. If a leak appears, shut off gas valve controls and adjust connections.
Then check the connections again.

NEVER TEST FOR GAS LEAKS WITH A MATCH OR OTHER FLAMES.

Remove all of the detergent solution from the cooktop.

Electronic Ignition System - initial lighting
Cooktop burners use electronic igniters rather than standing pilots. When the cooktop control

knob is pushed in and turned to the " " position, the system lights a spark to ignite the
burner. This sparking continues until the control knob is turned to the desired setting.

10)

Check the operation of the cooktop burners. Push in and turn each control knob to the maximum flame

position (

). The flame should light within 4 seconds.

If the burners do not light properly, turn the control knob to the   position. Ensure that the burner cap is
in the proper position. Ensure that the power supply cord is plugged in and that the circuit breaker or
house fuse has not blown. Ensure that the shut-off valve is on the "ON" position. Check operation again.
If a burner does not light at this point, contact your SMEG dealer for assistance.

Содержание PU 64-LP

Страница 1: ...rds inform you on how to reduce the risk of injury and as to what can occur if the instructions are not followed IMPORTANT Observe all government codes and ordinances WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death This conversion kit must be installed by a qualified service age...

Страница 2: ...regulator The regulator must be checked at a minimum water column of 1 inch 2 5 cm above the set pressure The inlet pressure to the regulator should be as follows for operation and checking the regulator setting NATURAL GAS Set pressure at 6 15 2 cm Supply pressure of 7 14 17 8 cm to 35 5 cm maximum LP GAS Minimum pressure of 10 25 4 cm Supply pressure of 14 35 5 cm The cooktop must be isolated fr...

Страница 3: ...rd remove the grids 2 lifting up one of the two horizontal spokes remove the burner caps 3 and flame caps 4 with wrench A available from authorized service centers open the bayonet clamps on the burner rings by levering on guides B After having removed all of the above described components lift the surface to gain access to the burners and gas taps ...

Страница 4: ... Front Left 4000 0 60 1500 0 40 Central A 12000 1 30 4000 Central A 11500 0 87 4000 0 58 B 0 71 B 0 48 Rear right 5200 0 95 1800 Rear right 5400 0 67 1800 0 40 Rear left 7200 1 13 3000 Front Left 7300 0 78 3000 0 50 PU 75 Natural gas PU 75 LP Qt Injector Qr Qt Injector Qr Qr BTU Ø mm BTU BTU Ø mm BTU BTU Central right A 12000 1 30 4000 Central right A 11500 0 87 4000 0 58 B 0 71 B 0 48 Central lef...

Страница 5: ... 10 mm Front left 3 16 4 5 mm Front left 1 10 2 5 mm Rear right 1 8 3 mm Rear right 1 10 2 5 mm Rear left 5 32 3 5 mm Rear left 1 8 3 mm PU 75 Natural gas PU 75 LP Air Shutter Air Shutter Front right 2 10 5 mm Front right 3 8 10 mm Front left 2 10 5 mm Front left 3 8 10 mm Central A 1 2 13 mm Central A 9 16 14 mm B 1 2 13 m B 9 16 14 mm Rear right 3 16 4 5 mm Rear right 1 10 2 5 mm Rear left 5 32 ...

Страница 6: ...o the following instructions Use a brush and liquid detergent to test all gas connections for leaks Bubbles around connections indicate a leak If a leak appears shut off gas valve controls and adjust connections Then check the connections again NEVER TEST FOR GAS LEAKS WITH A MATCH OR OTHER FLAMES Remove all of the detergent solution from the cooktop Electronic Ignition System initial lighting Coo...

Страница 7: ...imary air intake is closed too far C the flame is blue clear and stable and does not blow away from or wrap around the burner the air is set correctly 12 Check flame at the maximum flame position for a blue color It should be clean and soft in character No blowing or lifting of flame should occur Occasional orange flashes are normal and reflect different elements in the air or gas 13 Completely fi...

Отзывы: