Conversion Kit
6
4)
To adjust the cooktop for LP gas or to return to Natural Gas use, refer to the tables here below.
PU 64 - Natural gas
PU 64 - LP
Qt
Injector
Qr
Qt
Injector
Qr
Qr
BTU
Ø mm
BTU
BTU
Ø mm
BTU
BTU
Front Right
3800
0.82
1500
Front Right
4000
0.60
1500
0.40
Front Left
5200
0.95
1800
Front Left
5400
0.67
1800
0.40
Rear Right
10000
1.30
4000
Rear Right
10300
0.95
4000
0.58
Rear Left
7200
1.13
3000
Rear Left
7300
0.78
3000
0.50
PU 75 - Natural gas
PU 75 - LP
Qt
Injector
Qr
Qt
Injector
Qr
Qr
BTU
Ø mm
BTU
BTU
Ø mm
BTU
BTU
Front Right
3800
0.82
1500
Front Right
4000
0.60
1500
0.40
Front Left
3800
0.82
1500
Front Left
4000
0.60
1500
0.40
Central
A
12000
1.30
4000
Central
A
11500
0.87
4000
0.58
B
0.71
B
0.48
Rear right
5200
0.95
1800
Rear right
5400
0.67
1800
0.40
Rear left
7200
1.13
3000
Front Left
7300
0.78
3000
0.50
PU 75 - Natural gas
PU 75 - LP
Qt
Injector
Qr
Qt
Injector
Qr
Qr
BTU
Ø mm
BTU
BTU
Ø mm
BTU
BTU
Central
right
A
12000
1.30
4000
Central
right
A
11500
0.87
4000
0.58
B
0.71
B
0.48
Central
left
A
12000
1.30
4000
Central
left
A
11500
0.87
4000
0.58
B
0.71
B
0.48
Front Right
3800
0.82
1500
Front Right
4000
0.60
1500
0.40
Front Left
3800
0.82
1500
Front Left
4000
0.60
1500
0.40
Rear Right
7200
1.13
3000
Rear Right
7300
0.78
3000
0.50
Rear Left
5200
0.95
1800
Rear Left
5400
0.67
1800
0.40
NOTE: For reference parameters A and B on the central left and the
central right burners, see drawings on the right.