background image

Conversion Kit

6

4)

To adjust the cooktop for LP gas or to return to Natural Gas use, refer to the tables here below. 

  

  

PU 64 - Natural gas

PU 64 - LP

Qt

Injector

Qr

Qt

Injector

Qr

Qr

BTU

Ø mm

BTU

BTU

Ø mm

BTU

BTU

Front Right

3800

0.82

1500

Front Right

4000

0.60

1500

0.40

Front Left

5200

0.95

1800

Front Left

5400

0.67

1800

0.40

Rear Right

10000

1.30

4000

Rear Right

10300

0.95

4000

0.58

Rear Left

7200

1.13

3000

Rear Left

7300

0.78

3000

0.50

PU 75 - Natural gas

PU 75 - LP

Qt

Injector

Qr

Qt

Injector

Qr

Qr

BTU

Ø mm

BTU

BTU

Ø mm

BTU

BTU

Front Right

3800

0.82

1500

Front Right

4000

0.60

1500

0.40

Front Left

3800

0.82

1500

Front Left

4000

0.60

1500

0.40

Central

A

12000

1.30

4000

Central

A

11500

0.87

4000

0.58

B

0.71

B

0.48

Rear right

5200

0.95

1800

Rear right

5400

0.67

1800

0.40

Rear left

7200

1.13

3000

Front Left

7300

0.78

3000

0.50

PU 75 - Natural gas

PU 75 - LP

Qt

Injector

Qr

Qt

Injector

Qr

Qr

BTU

Ø mm

BTU

BTU

Ø mm

BTU

BTU

Central 

right

A

12000

1.30

4000

Central 

right

A

11500

0.87

4000

0.58

B

0.71

B

0.48

Central 

left

A

12000

1.30

4000

Central 

left

A

11500

0.87

4000

0.58

B

0.71

B

0.48

Front Right

3800

0.82

1500

Front Right

4000

0.60

1500

0.40

Front Left

3800

0.82

1500

Front Left

4000

0.60

1500

0.40

Rear Right

7200

1.13

3000

Rear Right

7300

0.78

3000

0.50

Rear Left

5200

0.95

1800

Rear Left

5400

0.67

1800

0.40

NOTE: For reference parameters A and B on the central left and the
central right burners, see drawings on the right.

Содержание PU 64-LP

Страница 1: ...rds inform you on how to reduce the risk of injury and as to what can occur if the instructions are not followed IMPORTANT Observe all government codes and ordinances WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death This conversion kit must be installed by a qualified service age...

Страница 2: ...regulator The regulator must be checked at a minimum water column of 1 inch 2 5 cm above the set pressure The inlet pressure to the regulator should be as follows for operation and checking the regulator setting NATURAL GAS Set pressure at 6 15 2 cm Supply pressure of 7 14 17 8 cm to 35 5 cm maximum LP GAS Minimum pressure of 10 25 4 cm Supply pressure of 14 35 5 cm The cooktop must be isolated fr...

Страница 3: ...rd remove the grids 2 lifting up one of the two horizontal spokes remove the burner caps 3 and flame caps 4 with wrench A available from authorized service centers open the bayonet clamps on the burner rings by levering on guides B After having removed all of the above described components lift the surface to gain access to the burners and gas taps ...

Страница 4: ... Front Left 4000 0 60 1500 0 40 Central A 12000 1 30 4000 Central A 11500 0 87 4000 0 58 B 0 71 B 0 48 Rear right 5200 0 95 1800 Rear right 5400 0 67 1800 0 40 Rear left 7200 1 13 3000 Front Left 7300 0 78 3000 0 50 PU 75 Natural gas PU 75 LP Qt Injector Qr Qt Injector Qr Qr BTU Ø mm BTU BTU Ø mm BTU BTU Central right A 12000 1 30 4000 Central right A 11500 0 87 4000 0 58 B 0 71 B 0 48 Central lef...

Страница 5: ... 10 mm Front left 3 16 4 5 mm Front left 1 10 2 5 mm Rear right 1 8 3 mm Rear right 1 10 2 5 mm Rear left 5 32 3 5 mm Rear left 1 8 3 mm PU 75 Natural gas PU 75 LP Air Shutter Air Shutter Front right 2 10 5 mm Front right 3 8 10 mm Front left 2 10 5 mm Front left 3 8 10 mm Central A 1 2 13 mm Central A 9 16 14 mm B 1 2 13 m B 9 16 14 mm Rear right 3 16 4 5 mm Rear right 1 10 2 5 mm Rear left 5 32 ...

Страница 6: ...o the following instructions Use a brush and liquid detergent to test all gas connections for leaks Bubbles around connections indicate a leak If a leak appears shut off gas valve controls and adjust connections Then check the connections again NEVER TEST FOR GAS LEAKS WITH A MATCH OR OTHER FLAMES Remove all of the detergent solution from the cooktop Electronic Ignition System initial lighting Coo...

Страница 7: ...imary air intake is closed too far C the flame is blue clear and stable and does not blow away from or wrap around the burner the air is set correctly 12 Check flame at the maximum flame position for a blue color It should be clean and soft in character No blowing or lifting of flame should occur Occasional orange flashes are normal and reflect different elements in the air or gas 13 Completely fi...

Отзывы: