Smeg PS9RU3 Скачать руководство пользователя страница 11

Instructions for the Installer

13

4. INSTALLING THE COOKTOP

1)

Remove the styrofoam protection and lift the cooktop in
order to extract it from the side protectors and the box.

2)

Connection to the gas mains should be made with a
flexible metal pipe and conforming to the provisions
defined by the current standard regulations in force. USE
A SOAPY SOLUTION TO CHECK THAT IT IS LEAK-
TIGHT.

NEVER USE A FLAME.

Follow these instructions to leak test the appliance:

The following procedures must be carried out to adjust
the gas supply pressure for LP operation of the cooktop:
1 Unscrew cap A on the pressure regulator
2 Turn it to where LP is printed
3 Re-tighten it and lock the pins in the slots provided.
4 There is an arrow printed on the back of the energy

regulator. The tip of the arrow indicates the end to be
connected to the cooktop connector.

Содержание PS9RU3

Страница 1: ...ne Follow the gas supplier s instructions lf you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas s...

Страница 2: ...g codes and ordinances WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do not s...

Страница 3: ...Instructions for the Installer 5 2 COOKTOP MEASUREMENTS...

Страница 4: ...ktop is to be installed must be sealed The cabinet opening dimensions that are shown must be used The given dimensions are the minimum clearances A grounded electrical supply is required See the 3 4 E...

Страница 5: ...62 mm 30 MAXIMUM 866 mm 34 3 16 600 mm 23 5 8 330 mm 13 The support strips must be properly sized and fastened so that they can support the appliance Gas line opening Wall everywhere 5 12 7 cm beneath...

Страница 6: ...Instructions for the Installer 8 3 2 Type B installation measurements Complete base B1 B2...

Страница 7: ...will be used for the passing of the gas connection while the right opening is for the electric connection For the fastening drill 4 holes 8 mm or 5 8 diameter in the positions shown alongside The dist...

Страница 8: ...ected to a regular gas supply 1 This installation must conform with all local codes and ordinances In the absence of local codes installation must conform with American National Standard National Fuel...

Страница 9: ...f the respective manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa 6 If the appliance is installed on an oven t...

Страница 10: ...SI NFPA 70 Electrical Code latest edition or the Canadian Electrical Code CSA and local codes and ordinances lf a mating outlet is not available it is the personal responsibility and obligation of the...

Страница 11: ...ns in force USE A SOAPY SOLUTION TO CHECK THAT IT IS LEAK TIGHT NEVER USE A FLAME Follow these instructions to leak test the appliance The following procedures must be carried out to adjust the gas su...

Страница 12: ...strips so that once they are tightened the cooktop is securely fastened to the structure 2 NOTE Use all of the brackets supplied with the appliance to fasten it to the support structure FASTENING FOR...

Страница 13: ...t D supplied between fitting C adaptor E Always place a suitable sealing medium such as Teflon tape between pressure regulator F and adaptor E and between pressure regulator F and pipe G The adaptor C...

Страница 14: ...o the appliance 2 The cooktop s electrical circuit can be checked for proper operation only after assembly has been completed and you have checked to ensure that all parts have been fitted properly 1...

Страница 15: ...equipped with a three pronge polarized plug grounding which fits in standard three pronged grounding wall outlets WARNING When servicing the controls label all wires prior to disconnection Wiring err...