WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, 

OBSERVE THE FOLLOWING: Installation Work And Electrical Wiring Must Be Done By Qualified Per-

son(s) In Accordance With All Applicable Codes And Standards, Including Fire-Rated Construction. 

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel 

burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and 

safety standards such as those published by the National Fire Protection Association (NFPA), and the 

American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code 

authorities. 

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 

Ducted fans must always be vented to the outdoors. 

W A R N I N G 

Electrical ground is required on this rangehood.

• If cold water pipe is interrupted by plastic, nonmetallic gaskets or other materials, DO NOT use for

grounding.

• DO NOT ground to a gas pipe.

• DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could 

result in electrical shock

•  Check with a qualified electrician if you are in doubt as to whether the rangehood is properly grounded.

• Failure to follow electrical requirements may result in a fire.

Содержание KSEGU24X

Страница 1: ...Manuel d Instructions Instructions Manual Manual de instrucciones Libretto Istruzioni KSEIG36XU Manuel d Instructions Instructions Manual Manual de instrucciones Libretto Istruzioni KSEIG36XU KSEGU24X ...

Страница 2: ...REMENTS 3 RECOMMENDATIONSANDSUGGESTIONS 6 DIMENSIONSandMAINPARTS 7 INSTALLATION 9 USE 13 CARE 14 3 6 7 8 10 11 EN 2 2 INDEX WARNINGSANDREQUIREMENTS 3 RECOMMENDATIONSANDSUGGESTIONS 6 DIMENSIONSandMAINPARTS 7 INSTALLATION 9 USE 13 CARE 14 ...

Страница 3: ...ed 4 Youcanfightthefirewithyourbacktoanexit ALLWALLANDFLOOROPENINGSWHERETHERANGEHOODISINSTALLEDMUSTBESEALED This rangehood requires at least 24 of clearance between the bottom of the rangehood and the cooking surface or countertop Consult the cooktop or range installation instructions given by the manufacturer before making any cutouts MOBILE HOME INSTALLATION The installation of this rangehood mu...

Страница 4: ...tional Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Thisapplianceshouldbeconnecteddirectly tothefuseddisconnect orcircuitbreaker throughflexible armored or nonmetallic sheathed copper cable Allow some slack in the cable so the appliance can be moved if servicing is ever necessary A UL Listed 1 2 conduit connector must be provided at each end of the power supply cable at...

Страница 5: ...ssociation NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors W A R N I N G Electricalgroundisrequiredonthisrangehood If cold water pipe is interrupted by plastic nonmetal...

Страница 6: ... backflow of exhaust gas The kitchen must have an opening communicating directly with the openairinordertoguaranteetheentryofcleanair USE Therangehoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchenodors Neverusethehoodforpurposesotherthanforwhichithasbendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation Adjust the flame intensity to direct it onto the bottom of the pan on...

Страница 7: ...Max 39 3 8 35 3 8 20 7 8 1 4 1 7 8 27 9 16 20 3 8 6 3 8 5 7 8 4 6 8 EN 7 7 Dimensions Ø 5 14 16 7 14 16 6 14 16 2 2 1 6 6 1 1 5 1 6 0 1 1 1 1 6 3 1 6 17 11 16 1 5 16 8 16 8 1 6 4 8 16 2 2 1 6 19 7 16 26 9 16 20 9 16 27 10 16 4 8 16 5 16 25 9 16 19 11 16 L 8x A 20 8 16 L 10x A 27 9 16 ...

Страница 8: ...osition by tightening the screws Vf from underneath the hood SCREWS FITTING The hood can be installed either directly on the bottom surface of the wall units min 25 9 16 above the hob Cut a fitted opening in the bottom surface of the wall unit as shown Fix using the 8 screws L provided EN 9 9 INSTALLATION SNAP ON FITTING The hood can be installed either directly on the bottom surface of the wall u...

Страница 9: ... grounding lead to the green screw provided Attach the White lead of the power supply to the White lead of the rangehood with a twist on type wire connector Attach the Black lead of the power supply to the Black lead of the rangehood with a twist on type wire connector Replace the cover Electricalconnection over from the Field Wiring Compartment with a phillips er Supply Cable through the electric...

Страница 10: ...the operating speed of the extractor 1 Low speed used for a continuous and silent air change in the presence of light cooking vapour 2 Medium speed suitable for most operating conditions given the optimum treated air flow noise level ratio 3 Maximum speed used for eliminating the highest cooking vapour emission including long periods L Light Switches the lighting system on and off M Motor Switches...

Страница 11: ...sing the lateral sliding handles Remove the filter retaining clips Replace the saturated synthetic filter Fix the new synthetic filter using the retaining clips and close the filter holder frame Charcoal filter recycling version REPLACING THE CHARCOAL FILTER Charcoal filter cannot be regenerated or washed It has to be substituted at least every 4 months or even more frequently when the use of the ...

Отзывы: