WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork. 

W A R N I N G 

•  Venting system MUST lead the air outside the building. 

• DO NOT expel the air through a ductwork in an attic or other enclosed space. 

• DO NOT use 4" laundry-type wall caps. 

• Flexible-type ductwork is NOT recommended. 

• DO NOT obstruct the flow of combustion and ventilation air. 

• Failure to follow venting requirements may result in a fire. 

ELECTRICAL REQUIREMENTS 

A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A timedelay fuse or 

circuit breaker is recommended. The fuse must be sized per local codes in accordance with the electrical rating 

of this unit as specified on the serial/rating plate located inside the unit near the field wiring compartment. THIS 

UNIT MUST BE CONNECTED WITH COPPER WIRE ONLY. Wire sizes must conform to the require-

ments of the National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances. Wire 

size and connections must conform with the rating of the appliance. Copies of the standard listed above may be 

obtained from: 

National Fire Protection Association 

Batterymarch Park 

Quincy, Massachusetts 02269 

This appliance should be connected directly to the fused disconnect (or circuit breaker) through flexible, armored 

or nonmetallic sheathed copper cable. Allow some slack in the cable so the appliance can be moved if servicing 

is ever necessary. A UL Listed, 1/2" conduit connector must be provided at each end of the power supply cable 

(at the appliance and at the junction box). 

When making the electrical connection, cut a 1 1/4" hole in the wall. A hole cut through wood must be sanded 

until smooth. A hole through metal must have a grommet. 

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, 

do not use this fan with any solid-state 

speed control device.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, 

OBSERVE THE FOLLOWING: 

Use this unit only for the purpose intended by the manufacturer. If you have any ques-

tions, contact the manufacturer. 

Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means 

to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, 

securely fasten a prominent warning device, such as a tag, to the service panel. 

CAUTION: 

For General Ventilating Use Only. Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors. 

Содержание KSEGU24X

Страница 1: ...Manuel d Instructions Instructions Manual Manual de instrucciones Libretto Istruzioni KSEIG36XU Manuel d Instructions Instructions Manual Manual de instrucciones Libretto Istruzioni KSEIG36XU KSEGU24X ...

Страница 2: ...REMENTS 3 RECOMMENDATIONSANDSUGGESTIONS 6 DIMENSIONSandMAINPARTS 7 INSTALLATION 9 USE 13 CARE 14 3 6 7 8 10 11 EN 2 2 INDEX WARNINGSANDREQUIREMENTS 3 RECOMMENDATIONSANDSUGGESTIONS 6 DIMENSIONSandMAINPARTS 7 INSTALLATION 9 USE 13 CARE 14 ...

Страница 3: ...ed 4 Youcanfightthefirewithyourbacktoanexit ALLWALLANDFLOOROPENINGSWHERETHERANGEHOODISINSTALLEDMUSTBESEALED This rangehood requires at least 24 of clearance between the bottom of the rangehood and the cooking surface or countertop Consult the cooktop or range installation instructions given by the manufacturer before making any cutouts MOBILE HOME INSTALLATION The installation of this rangehood mu...

Страница 4: ...tional Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Thisapplianceshouldbeconnecteddirectly tothefuseddisconnect orcircuitbreaker throughflexible armored or nonmetallic sheathed copper cable Allow some slack in the cable so the appliance can be moved if servicing is ever necessary A UL Listed 1 2 conduit connector must be provided at each end of the power supply cable at...

Страница 5: ...ssociation NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors W A R N I N G Electricalgroundisrequiredonthisrangehood If cold water pipe is interrupted by plastic nonmetal...

Страница 6: ... backflow of exhaust gas The kitchen must have an opening communicating directly with the openairinordertoguaranteetheentryofcleanair USE Therangehoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchenodors Neverusethehoodforpurposesotherthanforwhichithasbendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation Adjust the flame intensity to direct it onto the bottom of the pan on...

Страница 7: ...Max 39 3 8 35 3 8 20 7 8 1 4 1 7 8 27 9 16 20 3 8 6 3 8 5 7 8 4 6 8 EN 7 7 Dimensions Ø 5 14 16 7 14 16 6 14 16 2 2 1 6 6 1 1 5 1 6 0 1 1 1 1 6 3 1 6 17 11 16 1 5 16 8 16 8 1 6 4 8 16 2 2 1 6 19 7 16 26 9 16 20 9 16 27 10 16 4 8 16 5 16 25 9 16 19 11 16 L 8x A 20 8 16 L 10x A 27 9 16 ...

Страница 8: ...osition by tightening the screws Vf from underneath the hood SCREWS FITTING The hood can be installed either directly on the bottom surface of the wall units min 25 9 16 above the hob Cut a fitted opening in the bottom surface of the wall unit as shown Fix using the 8 screws L provided EN 9 9 INSTALLATION SNAP ON FITTING The hood can be installed either directly on the bottom surface of the wall u...

Страница 9: ... grounding lead to the green screw provided Attach the White lead of the power supply to the White lead of the rangehood with a twist on type wire connector Attach the Black lead of the power supply to the Black lead of the rangehood with a twist on type wire connector Replace the cover Electricalconnection over from the Field Wiring Compartment with a phillips er Supply Cable through the electric...

Страница 10: ...the operating speed of the extractor 1 Low speed used for a continuous and silent air change in the presence of light cooking vapour 2 Medium speed suitable for most operating conditions given the optimum treated air flow noise level ratio 3 Maximum speed used for eliminating the highest cooking vapour emission including long periods L Light Switches the lighting system on and off M Motor Switches...

Страница 11: ...sing the lateral sliding handles Remove the filter retaining clips Replace the saturated synthetic filter Fix the new synthetic filter using the retaining clips and close the filter holder frame Charcoal filter recycling version REPLACING THE CHARCOAL FILTER Charcoal filter cannot be regenerated or washed It has to be substituted at least every 4 months or even more frequently when the use of the ...

Отзывы: