READ AND SAVE THESE INSTRUCTIONS 

The Installer must leave these instructions with the homeowner. 

The homeowner must keep these instructions for future reference and for local electrical inspectors’ use. 

READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD 

WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: 

Never leave surface units unattended at 

high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting. Always

turn hood ON when cooking at high heat or when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flam-

bé). Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. Use proper pan size. Always

use cookware appropriate for the size of the surface element.

WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP 

GREASE FIRE, OBSERVE THE FOLLOWING: SMOTHER FLAMES 

with a close-fitting lid, cookie sheet, or 

metal tray, then turn off the burner

.

BE CAREFUL TO PREVENT BURNS

.

 If the flames do not go out immedi-

ately

EVACUATE AND CALL THE FIRE DEPARTMENT. NEVER PICK UP A FLAMING PAN - 

You may be 

burned

.

 DO NOT USE WATER, 

including wet dishcloths or towels - a violent steam explosion will result. Use 

an extinguisher ONLY if: 1. You know you have a Class ABC extinguisher, and you already know how to op-

erate it. 2. The fire is small and contained in the area where it started. 3. The fire department is being called. 4. 

You can fight the fire with your back to an exit

.

ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST BE SEALED. 

This rangehood requires at least 24" of clearance between the bottom of the rangehood and the cooking surface 

or countertop. Consult the cooktop or range installation instructions given by the manufacturer before making 

any cutouts. MOBILE HOME INSTALLATION. The installation of this rangehood must conform to the 

Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly Federal Standard 

for Mobile Home Construction and Safety, Title 24, HUD, Part 280). Four wire power supply must be used and 

the appliance wiring must be revised. See Electrical Requirements. 

VENTING REQUIREMENTS 

CAUTION - 

To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces 

within walls or ceilings or into attics, crawl spaces, or garages".

Check which venting method is best for your application. Ductwork can extend either through the wall or the 

roof. The length of the ductwork and the number of elbows should be kept to a minimum to provide efficient 

performance. The size of the ductwork should be constant. Do not install two elbows together. Use duct tape to 

seal all joints in the ductwork system. Use caulking to seal exterior wall or floor opening around the cap. 

Flexible ductwork is not recommended. Flexible ductwork creates back pressure and air turbulence that greatly 

reduces performance. 

Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts. Do not cut a joist or 

stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed. 

Содержание KSEGU24X

Страница 1: ...Manuel d Instructions Instructions Manual Manual de instrucciones Libretto Istruzioni KSEIG36XU Manuel d Instructions Instructions Manual Manual de instrucciones Libretto Istruzioni KSEIG36XU KSEGU24X ...

Страница 2: ...REMENTS 3 RECOMMENDATIONSANDSUGGESTIONS 6 DIMENSIONSandMAINPARTS 7 INSTALLATION 9 USE 13 CARE 14 3 6 7 8 10 11 EN 2 2 INDEX WARNINGSANDREQUIREMENTS 3 RECOMMENDATIONSANDSUGGESTIONS 6 DIMENSIONSandMAINPARTS 7 INSTALLATION 9 USE 13 CARE 14 ...

Страница 3: ...ed 4 Youcanfightthefirewithyourbacktoanexit ALLWALLANDFLOOROPENINGSWHERETHERANGEHOODISINSTALLEDMUSTBESEALED This rangehood requires at least 24 of clearance between the bottom of the rangehood and the cooking surface or countertop Consult the cooktop or range installation instructions given by the manufacturer before making any cutouts MOBILE HOME INSTALLATION The installation of this rangehood mu...

Страница 4: ...tional Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Thisapplianceshouldbeconnecteddirectly tothefuseddisconnect orcircuitbreaker throughflexible armored or nonmetallic sheathed copper cable Allow some slack in the cable so the appliance can be moved if servicing is ever necessary A UL Listed 1 2 conduit connector must be provided at each end of the power supply cable at...

Страница 5: ...ssociation NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors W A R N I N G Electricalgroundisrequiredonthisrangehood If cold water pipe is interrupted by plastic nonmetal...

Страница 6: ... backflow of exhaust gas The kitchen must have an opening communicating directly with the openairinordertoguaranteetheentryofcleanair USE Therangehoodhasbeendesignedexclusivelyfordomesticusetoeliminatekitchenodors Neverusethehoodforpurposesotherthanforwhichithasbendesigned Neverleavehighnakedflamesunderthehoodwhenitisinoperation Adjust the flame intensity to direct it onto the bottom of the pan on...

Страница 7: ...Max 39 3 8 35 3 8 20 7 8 1 4 1 7 8 27 9 16 20 3 8 6 3 8 5 7 8 4 6 8 EN 7 7 Dimensions Ø 5 14 16 7 14 16 6 14 16 2 2 1 6 6 1 1 5 1 6 0 1 1 1 1 6 3 1 6 17 11 16 1 5 16 8 16 8 1 6 4 8 16 2 2 1 6 19 7 16 26 9 16 20 9 16 27 10 16 4 8 16 5 16 25 9 16 19 11 16 L 8x A 20 8 16 L 10x A 27 9 16 ...

Страница 8: ...osition by tightening the screws Vf from underneath the hood SCREWS FITTING The hood can be installed either directly on the bottom surface of the wall units min 25 9 16 above the hob Cut a fitted opening in the bottom surface of the wall unit as shown Fix using the 8 screws L provided EN 9 9 INSTALLATION SNAP ON FITTING The hood can be installed either directly on the bottom surface of the wall u...

Страница 9: ... grounding lead to the green screw provided Attach the White lead of the power supply to the White lead of the rangehood with a twist on type wire connector Attach the Black lead of the power supply to the Black lead of the rangehood with a twist on type wire connector Replace the cover Electricalconnection over from the Field Wiring Compartment with a phillips er Supply Cable through the electric...

Страница 10: ...the operating speed of the extractor 1 Low speed used for a continuous and silent air change in the presence of light cooking vapour 2 Medium speed suitable for most operating conditions given the optimum treated air flow noise level ratio 3 Maximum speed used for eliminating the highest cooking vapour emission including long periods L Light Switches the lighting system on and off M Motor Switches...

Страница 11: ...sing the lateral sliding handles Remove the filter retaining clips Replace the saturated synthetic filter Fix the new synthetic filter using the retaining clips and close the filter holder frame Charcoal filter recycling version REPLACING THE CHARCOAL FILTER Charcoal filter cannot be regenerated or washed It has to be substituted at least every 4 months or even more frequently when the use of the ...