A

Turns the lighting system on and off at maximum 
intensity. 

On/Off 

Turns the lighting system on and off in Courtesy Light 
mode. 

On/Off 

B

Turns the Motor off. 

 

Press and hold for approximately 5 seconds to Lock / 
Unlock the Keyboard, for example in order to clean the 
surface. 

The buttons turn light up one at a time in cycle. 

C

Turns the Motor on at Speed one. 

On/Off 

D

Turns the Motor on at Speed two. 

On/Off 

E

Turns the Motor on at Speed three. 

On/Off 

F

Activates/Deactivates 

intensive

 speed from any other 

speed, including motor off. This speed is set to operate 
for 10 minutes, after which the system returns to the 
speed that was set before. Suitable to deal with 
maximum levels of cooking fumes. Can also be 
deactivated by pressing button 

B

.

Flashes once a second. 

Press and  hold the button for approximately 5 seconds, 
with all the loads turned off (Motor and Lights), to turn 
the Activated Charcoal Filter alarm on/off.  

Button B

 (Flashes twice)-Alarm Activated. 

Button B

 (Flashes once)-Alarm Deactivated. 

G

24H function 

Turns the motor On/Off at speed one and allows 
recirculation for 10 minutes every hour. It cannot be 
activated if the 

Intensive

 or 

Delay

 functions are in use. 

On/Off 

When the filters alarm is triggered, the alarm can be 
reset by pressing and holding this button for 
approximately 5 seconds.  
These indications are only visible when the motor is 
turned off.

B

 flashes three times. 

When the procedure terminates, the indication shown 
previously turns off: 

Button G flashes

, indicating the need to wash the metal 

grease filters. The alarm is triggered after the Hood has 
been in operation for 100 working hours.  

Button G flashes

, indicating the need to change the 

activated charcoal filters, and also to wash the metal grease 
filters. The alarm is triggered after the Hood has been in 
operation for 200 working hours. 

H

Delay function 

Activates/Deactivates automatic switch-off with a 30’ 
delay. Suitable to complete elimination of residual 
odours. Can be activated from any position. It cannot 
be activated if the 

Intensive

 or 

24H

 functions are in 

use. 

On/Off 

Press and hold the button for approximately 5 seconds, 
with all the loads turned off (Motor and Lights), to turn 
the Remote control on/off.  

Button B

 (Flashes twice)-Remote control Activated. 

Button B

 (Flashes once)-Remote control Deactivated. 

R

Remote control receiver. 

Содержание KSE920X

Страница 1: ...Libretto di Istruzioni Manuel d Instructions Instructions Manual Gebruiksaanwijzing Bedienungsanleitung Bruksanvisning Manual de instrucciones Manual de Instru es Brugsvejledning KSE920X...

Страница 2: ...COMMENDATIONS AND SUGGESTIONS 20 CHARACTERISTICS 21 INSTALLATION 22 USE 25 MAINTENANCE 26 INHOUDSOPGAVE ADVIEZEN EN SUGGESTIES 28 EIGENSCHAPPEN 29 INSTALLATIE 30 GEBRUIK 33 ONDERHOUD 34 INHALTSVERZEIC...

Страница 3: ...53 INSTALACI N 54 USO 57 MANTENIMIENTO 58 NDICE CONSELHOS E SUGEST ES 60 CARACTER STICAS 61 INSTALA O 62 UTILIZA O 65 MANUTEN O 66 68 69 70 73 74 INDHOLD R D OG ANVISNINGER 76 APPARATBESKRIVELSE 77 IN...

Страница 4: ...er to prevent any risks USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has been designed Neve...

Страница 5: ...n 2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 10 1 Damper 150 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fix...

Страница 6: ...w the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as i...

Страница 7: ...up plied To install a 120 pipe To install a 120 mm air exhaust connection insert the redu cer flange 9 on the dumper 10 Fix the pipe in position using sufficient pipe clamps not sup plied Remove any a...

Страница 8: ...n the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets by using the 4 screws 12c 2 9 x 9 5 supplied Make sure...

Страница 9: ...speed one and allows recirculation for 10 minutes every hour It cannot be activated if the Intensive or Delay functions are in use On Off When the filters alarm is triggered the alarm can be reset by...

Страница 10: ...ntly if use is particularly intensive Resetting the alarm signal Turn the Lights and the Suction motor off then disable the 24h function if enabled Press button G and hold for approximately 5 seconds...

Страница 11: ...larm DEACTIVATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Turn the Lights and the Suction Motor off Press button G and hold for approximately 5 seconds See paragraph on Use Ch...