ELECTRICAL CONNECTION 

•  Connect the hood to the mains through a two-pole switch hav-

ing a contact gap of at least 3 mm. 

•  Remove the grease filters (see paragraph Maintenance) being 

sure that the connector of the feeding cable is correctly inserted 
in the socket placed on the side of the fan. 

Flue assembly 

Upper exhaust flue

•  Slightly widen the two sides of the upper flue and hook them 

behind the brackets 

7.2.1

, making sure that they are well 

seated. 

•  Secure the sides to the brackets by using the 4 screws 

12c

 (2,9 

x 9,5) supplied. 

•   Make sure that the outlet of the extensions pieces is aligned 

with the chimney outlets. 

Lower exhaust flue

•  Slightly widen the two sides of the flue and hook them be-

tween the upper flue and the wall,   making sure that they are 
well seated. 

•   Fix the lower part laterally to the hood body by using the 2 

screws 

12c

 (2,9 x 9,5) supplied. 

12c

2.1

2.2

2

7.2.1

12c

Содержание KSE920X

Страница 1: ...Libretto di Istruzioni Manuel d Instructions Instructions Manual Gebruiksaanwijzing Bedienungsanleitung Bruksanvisning Manual de instrucciones Manual de Instru es Brugsvejledning KSE920X...

Страница 2: ...COMMENDATIONS AND SUGGESTIONS 20 CHARACTERISTICS 21 INSTALLATION 22 USE 25 MAINTENANCE 26 INHOUDSOPGAVE ADVIEZEN EN SUGGESTIES 28 EIGENSCHAPPEN 29 INSTALLATIE 30 GEBRUIK 33 ONDERHOUD 34 INHALTSVERZEIC...

Страница 3: ...53 INSTALACI N 54 USO 57 MANTENIMIENTO 58 NDICE CONSELHOS E SUGEST ES 60 CARACTER STICAS 61 INSTALA O 62 UTILIZA O 65 MANUTEN O 66 68 69 70 73 74 INDHOLD R D OG ANVISNINGER 76 APPARATBESKRIVELSE 77 IN...

Страница 4: ...er to prevent any risks USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has been designed Neve...

Страница 5: ...n 2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 10 1 Damper 150 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fix...

Страница 6: ...w the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as i...

Страница 7: ...up plied To install a 120 pipe To install a 120 mm air exhaust connection insert the redu cer flange 9 on the dumper 10 Fix the pipe in position using sufficient pipe clamps not sup plied Remove any a...

Страница 8: ...n the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets by using the 4 screws 12c 2 9 x 9 5 supplied Make sure...

Страница 9: ...speed one and allows recirculation for 10 minutes every hour It cannot be activated if the Intensive or Delay functions are in use On Off When the filters alarm is triggered the alarm can be reset by...

Страница 10: ...ntly if use is particularly intensive Resetting the alarm signal Turn the Lights and the Suction motor off then disable the 24h function if enabled Press button G and hold for approximately 5 seconds...

Страница 11: ...larm DEACTIVATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Turn the Lights and the Suction Motor off Press button G and hold for approximately 5 seconds See paragraph on Use Ch...

Отзывы: