7.3

11

12a

320

X

116

1÷2

116

650 min.

7.2.1

INSTALLATION

Wall drilling and bracket fixing 

Wall marking: 
•  Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the 

centre of the area in which the hood will be installed. 

•   Draw a horizontal line at 650 mm above the hob. 
•   Place  bracket 

7.2.1

on the wall as shown about 1-2 mm from the ceiling or upper limit 

aligning the centre (notch) with the vertical reference line. 

•   Mark the wall at the centres of the holes in the bracket. 
•   Place bracket 

7.2.1 

on the wall as shown at X mm below the first bracket (X = height of the 

upper chimney section supplied), aligning the centre (notch) with the vertical line. 

•   Mark the wall at the centres of the holes in the bracket. 
•  Mark a reference point as indicated at 116 mm from the vertical reference line and 320 mm 

above the horizontal reference line. 

•   Repeat this operation on the other side. 
•   Drill ø 8 mm holes at all the centre points marked. 
•   Insert the wall plugs 

11

in the holes. 

•   Fix the lower bracket 

7.2.1 

using the 

12a

screws (4,2 x 44,4) supplied. 

•  Fix the upper bracket 

7.2.1 

and the air outlet connection support 

7.3

together using the 2 

screws 

12a

(4,2 x 44,4) supplied. 

•  Insert the two screws 

12a

(4,2 x 44,4) supplied in the hood body fixing holes, leaving a gap 

of 5-6 mm between the wall and the head of the screw.

Содержание KSE920X

Страница 1: ...Libretto di Istruzioni Manuel d Instructions Instructions Manual Gebruiksaanwijzing Bedienungsanleitung Bruksanvisning Manual de instrucciones Manual de Instru es Brugsvejledning KSE920X...

Страница 2: ...COMMENDATIONS AND SUGGESTIONS 20 CHARACTERISTICS 21 INSTALLATION 22 USE 25 MAINTENANCE 26 INHOUDSOPGAVE ADVIEZEN EN SUGGESTIES 28 EIGENSCHAPPEN 29 INSTALLATIE 30 GEBRUIK 33 ONDERHOUD 34 INHALTSVERZEIC...

Страница 3: ...53 INSTALACI N 54 USO 57 MANTENIMIENTO 58 NDICE CONSELHOS E SUGEST ES 60 CARACTER STICAS 61 INSTALA O 62 UTILIZA O 65 MANUTEN O 66 68 69 70 73 74 INDHOLD R D OG ANVISNINGER 76 APPARATBESKRIVELSE 77 IN...

Страница 4: ...er to prevent any risks USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has been designed Neve...

Страница 5: ...n 2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 10 1 Damper 150 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fix...

Страница 6: ...w the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as i...

Страница 7: ...up plied To install a 120 pipe To install a 120 mm air exhaust connection insert the redu cer flange 9 on the dumper 10 Fix the pipe in position using sufficient pipe clamps not sup plied Remove any a...

Страница 8: ...n the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets by using the 4 screws 12c 2 9 x 9 5 supplied Make sure...

Страница 9: ...speed one and allows recirculation for 10 minutes every hour It cannot be activated if the Intensive or Delay functions are in use On Off When the filters alarm is triggered the alarm can be reset by...

Страница 10: ...ntly if use is particularly intensive Resetting the alarm signal Turn the Lights and the Suction motor off then disable the 24h function if enabled Press button G and hold for approximately 5 seconds...

Страница 11: ...larm DEACTIVATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Turn the Lights and the Suction Motor off Press button G and hold for approximately 5 seconds See paragraph on Use Ch...

Отзывы: