Smeg KIV90XT-1 Скачать руководство пользователя страница 5

 

 

 

 

 

EN 

5

 

Components 

Ref.  Q.ty  Product Components  

1  Hood Canopy complete with: Controls, Lights, Filters 

2

 

1  Telescopic chimney made up of: 

2.1

 

1  Upper chimney  

2.2

 

1  Lower chimney  

7.1

 

1  Telescopic frame complete with Suction fan, made up 

of: 

7.1a

 1 Upper 

frame 

7.1b

 1 Lower 

frame 

8a

 

1  Rh Air Outlet Directional Grille 

8b

 

1  Lh Air Outlet Directional Grille 

9

 

1  Reduction flange ø 150-120 mm 

10

 1 

Dumper 

14.1

 

1  Air Outlet Connector Extension 

15

 

1  Air Outlet Connector  

24

 1 

Connection 

box 

25

 

 

Pipe clamps (not included) 

26

 2 

Cable 

clamps 

27

 1 

Finishing 

plug 

 

 
Ref. Q.ty Installation 

Components 

11

 

4  Wall Plugs ø 10 

12c

 

6  Screws 2,9 x 6,5 

12e

 

2  Screws 2,9 x 9,5 

12f

 

2  Screws M4 x 80 

12g

 

4  Screws M6 x 80 

12h

 

4  Screws 5,2 x 70 

12q

 

4  Screws 3,5 x 9,5 

21

 1 

Drilling 

template 

22

 

8  6.4 mm int. dia washers 

23

 4 

M6 

nuts 

 

 

 

 Q.ty 

Documentation 

 

1

 

Instruction booklet 

 

 

12c

7.1a

7.1

22

23

12h

7.1b

2

2.1

2.2

8b

8a

12c

11

21

12g

1

25

24

12e

14.1

15

9

12c

26

27

12f

12q

22

10

Содержание KIV90XT-1

Страница 1: ...Instructions Manual Manual de instrucciones Manual de Instru es KIV90XT 1...

Страница 2: ...CHARACTERISTICS 4 INSTALLATION 6 USE 10 MAINTENANCE 11 NDICE CONSEJOS Y SUGERENCIAS 13 CARACTER STICAS 14 INSTALACI N 16 USO 20 MANTENIMIENTO 21 NDICE CONSELHOS E SUGEST ES 23 CARACTER STICAS 24 INST...

Страница 3: ...der to prevent any risks USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has been designed Nev...

Страница 4: ...EN 4 4 CHARACTERISTICS Dimensions 650 290 70 90 132 310 150 350 700 Min 780 Max 1070 36 Min 500mm Min 650mm...

Страница 5: ...150 120 mm 10 1 Dumper 14 1 1 Air Outlet Connector Extension 15 1 Air Outlet Connector 24 1 Connection box 25 Pipe clamps not included 26 2 Cable clamps 27 1 Finishing plug Ref Q ty Installation Comp...

Страница 6: ...ilings with wall thickness of 20 mm drill 10 mm immediately insert the Dowels 11 supplied For wooden beam ceilings drill according to the wood screws used For wooden shelf drill 7 mm For the power sup...

Страница 7: ...n the slotted holes The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device On completion check that the base...

Страница 8: ...the extension pieces 14 1 is hori zontally and vertically aligned with the chimney outlets Otherwise remove the lower chimney and adjust the position by inverting the extension pieces for air outlet...

Страница 9: ...ed on the galva nized diffuser support as shown in fig 2 Position the finishing plug 27 over the housing in the diffuser support fixing it us ing a screw 12e 2 9 x 9 5 and applying the 2 cable clamp e...

Страница 10: ...aturation of the activated charcoal filters T2 Turn the suction motor on at speed two On Press and hold for approximately 5 seconds with all the loads turned off Motor and Lights to enable disable the...

Страница 11: ...r more frequently if use is particularly intensive Resetting the alarm signal Press button T1 see the paragraph on Use Cleaning the Filters Remove the Filters one at a time pushing them towards the ba...

Страница 12: ...tivated Charcoal Filter saturation alarm DEACTI VATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Press button T1 see the paragraph on Use Changing the Filter Remove the Metal gr...

Отзывы: