RECOMMENDATIONS AND SUGGESTIONS

 

  The Instructions for Use apply to several versions of this appliance. Accordingly, you may 

find descriptions of individual features that do not apply to your specific appliance. 

INSTALLATION 

•  The manufacturer will not be held liable for any damages resulting from incorrect or im-

proper installation. 

•  The minimum safety distance between the cooker top and the extractor hood is 650 mm 

(some models can be installed at a lower height, please refer to the paragraphs on work-

ing dimensions and installation). 

•  Check that the mains voltage corresponds to that indicated on the rating plate fixed to the 

inside of the hood. 

•  For Class I appliances, check that the domestic power supply guarantees adequate 

earthing. 

  Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. 

The route of the flue must be as short as possible. 

•  Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, 

fireplaces, etc.). 

•  If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appli-

ances), a sufficient degree of aeration must be guaranteed in the room in order to prevent 

the backflow of exhaust gas. The kitchen must have an opening communicating directly 

with the open air in order to guarantee the entry of clean air.

 

When the cooker hood is 

used in conjunction with appliances supplied with energy other than electric, the negative 

pressure in the room must not exceed 0,04 mbar to prevent fumes being drawn back into 

the room by the cooker hood. 

•  In the event of damage to the power cable, it must be replaced by the manufacturer or by 

the technical service department, in order to prevent any risks. 

USE 

•  The extractor hood has been designed exclusively for domestic use to eliminate kitchen 

smells. 

•  Never use the hood for purposes other than for which it has been designed. 

•  Never leave high naked flames under the hood when it is in operation. 

•  Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it 

does not engulf the sides. 

•  Deep fat fryers must be continuously monitored during use: overheated oil can burst into 

flames. 

•  Do not flambè under the range hood; risk of fire  

•  This appliance is not intended for use by persons (including children) with reduced physi-

cal, sensory or mental capabilities, or lack of experience and knowledge, unless they have 

been given supervision or instruction concerning use of the appliance by a person respon-

sible for their safety. 

•  Children should be supervised to ensure that they do not play with the appliance. 

•  “ CAUTION: Accessible parts may become hot when used with cooking appliances.”. 

MAINTENANCE 

•  Switch off or unplug the appliance from the mains supply before carrying out any mainte-

nance work. 

•  Clean and/or replace the Filters after the specified time period (Fire hazard). 

•  Clean the hood using a damp cloth and a neutral liquid detergent. 

 

The symbol 

 on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be 

handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of 
correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by 
inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your 
household waste disposal service or the shop where you purchased the product

 

 

Содержание KIV90XT-1

Страница 1: ...Instructions Manual Manual de instrucciones Manual de Instru es KIV90XT 1...

Страница 2: ...CHARACTERISTICS 4 INSTALLATION 6 USE 10 MAINTENANCE 11 NDICE CONSEJOS Y SUGERENCIAS 13 CARACTER STICAS 14 INSTALACI N 16 USO 20 MANTENIMIENTO 21 NDICE CONSELHOS E SUGEST ES 23 CARACTER STICAS 24 INST...

Страница 3: ...der to prevent any risks USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has been designed Nev...

Страница 4: ...EN 4 4 CHARACTERISTICS Dimensions 650 290 70 90 132 310 150 350 700 Min 780 Max 1070 36 Min 500mm Min 650mm...

Страница 5: ...150 120 mm 10 1 Dumper 14 1 1 Air Outlet Connector Extension 15 1 Air Outlet Connector 24 1 Connection box 25 Pipe clamps not included 26 2 Cable clamps 27 1 Finishing plug Ref Q ty Installation Comp...

Страница 6: ...ilings with wall thickness of 20 mm drill 10 mm immediately insert the Dowels 11 supplied For wooden beam ceilings drill according to the wood screws used For wooden shelf drill 7 mm For the power sup...

Страница 7: ...n the slotted holes The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device On completion check that the base...

Страница 8: ...the extension pieces 14 1 is hori zontally and vertically aligned with the chimney outlets Otherwise remove the lower chimney and adjust the position by inverting the extension pieces for air outlet...

Страница 9: ...ed on the galva nized diffuser support as shown in fig 2 Position the finishing plug 27 over the housing in the diffuser support fixing it us ing a screw 12e 2 9 x 9 5 and applying the 2 cable clamp e...

Страница 10: ...aturation of the activated charcoal filters T2 Turn the suction motor on at speed two On Press and hold for approximately 5 seconds with all the loads turned off Motor and Lights to enable disable the...

Страница 11: ...r more frequently if use is particularly intensive Resetting the alarm signal Press button T1 see the paragraph on Use Cleaning the Filters Remove the Filters one at a time pushing them towards the ba...

Страница 12: ...tivated Charcoal Filter saturation alarm DEACTI VATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Press button T1 see the paragraph on Use Changing the Filter Remove the Metal gr...

Отзывы: