22
Thermostop
Set as “on” = minimum rinsing temperature as set, (see
boiler temperature above) regardless of intake water
temperature; the cycle duration may be a few seconds
longer than the nominal length.
Set as “off” = the minimum rinsing temperature might be a
few degrees lower than the setting if hot intake water is not
used.
If the thermostop device is set “off” the rinsing °
t
are no longer monitored and the user is
responsible for ensuring that the minimum correct °
t
are maintained for the tank and boiler. It is
particularly
important
to
check
the
intake
water
temperature.
Also refer to the insufficient washing/drying /foam in tank point of the “troubleshooting” section :
restore °
t
Stop ON and/or connect the appliance to a hot water supply.
High speed (FST) or economy (ECO) filling (FILL)
Fast start (FST): starts the dishwasher in less than the
standard time; leads to higher water consumption for the
first cycle start.
Eco start (ECO): starts the dishwasher in standard time, with
no added water consumption.
On: enabled – OFF: disabled.
Cycles performed counter
Shows the count of the total cycles performed by the
dishwasher since installation.
This parameter cannot be modified or reset unless the
software is reprogrammed.
USER program duration customisation (optional, only if installed)
USER. 03.10 is the only program which can be customised.
Scroll through the setup parameters to display USER.P1,
P2….. followed by two dashes (e.g. P2--). Keep pressing the P
button until USER appears followed by the duration
(e.g. USER. 03.10).
Содержание HTY511DH