2. Connection to Main Water Supply
Before Installation
1. The icemaker requires the water pressure of 1.5 -
8.5kgf/cm
2
. (It is acceptable if city water fills a cup of
180cc with water for 3 seconds)
2. Install booster pump where the city water pressure is
below 1.5kgf/cm
2
for normal operation of water and ice
dispenser.
3. The total length of water pipe shall be less than 12m. Do
not bend the pipe at right angle. If the length is more
than 12m, there will be troubles on water supply due to
water pressure drop.
4. Please install water pipe where there is no heat around.
2-1. Check all correct items (In case of External Filter
Models).
2-2. Connection to the Appliance (In case of External or Internal Filter Models).
HOW TO INSTALL REFRIGERATOR
- 9 -
1 x Connector type Water Filter
2 x Clips
1 x 8mm Water Pipe
Plastic Pipe Connector
Rubber Washer
At the back of the appliance you
will see the water inlet valve.
(See Fig. A)
You now need to cut the water pipe to the right lenght for
connection of the water filter.
It is suggested that
approximately 1.5mm of pipe is used
- this should allow the filter to be located in an accessible
position (for periodic replacement) and also allow some
slack in the pipe behind the machine so that it con be
pulled out for cleaning or servicing purposes.
Unscrew the metal thearded
collar and place it over one end
of the water pipe. (See Fig. B)
Firmly push the water pipe onto
the water inlet valve and tighten
up the metal collar. (See Fig. C)
You must also ensure that the cut is square and not
at any sort of angle as this could cause a leak.