![Smeg GW-L227 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/smeg/gw-l227/gw-l227_service-manual_1303940028.webp)
TROUBLE DIAGNOSIS
Display PCB
Is the connection loose?
Replace the
Display PCB
Display PCB
Is the voltage between pins 2 and
pin 5 of CON101?
Yes
No
Yes
Reconnect
Is the joint connection
loose In the Hinge?
Yes
No
Communication Error
MAIN
PCB
DISPLAY
PCB
3
4
5
6
Hinge
RD(Rx)
BN(Tx)
BO(GND)
WH/BK(12V)
RD(Tx)
BN(Rx)
BO(GND)
WH/BK(12V)
1
4
2
3
4
3
2
1
CON6
CON101
1
4
2
3
Rx: Receiver
Tx: Transmitter
Wiring diagram
0 V or 5 V
pin2 To pin3
Result
Test Point
Receiver fail Voltages
N0
Is Er-CO displayed?
Yes
Display PCB
Is the voltage between pin1
and pin3 of CON101 0 V or 5 V?
Yes
0 V or 5 V
pin1 To pin3
Result
Test Point
Transmitter Voltages
N0
Replace the
Display PCB
Reconnect
Pin3
Pin2
Pin3
Pin1
Содержание GW-L227
Страница 104: ...MAY 2009 Printed in EU ...