background image

To start rapid freeze mode; 

  Press ‘Mode/Set’ button. 

  Press ‘Up’ or ‘Down’ button until <tb> is displayed. 

  Press ‘Mode/Set’ button for two seconds to start rapid freeze. 

 

To stop rapid freeze; 

During rapid freeze, press ‘Mode/Set’ button for two seconds. <tb> will flash five times 
and then return to normal operation. 
 

Setting Defrost Frequency- 

The unit is preset to defrost every 6 hours.  The defrost frequency can be set from 4 to 
12 hours with a 2 hour interval.  During defrost <dF> is displayed instead of cabinet 
temperature. 
To set defrost frequency; 

  Press ‘Mode/Set’ button. 

  Press ‘Up’ or ‘Down’ button until <dt> is displayed. 

  Press ‘Mode/Set’ button to see current defrost frequency setting. 

  Press ‘Up’ or ‘Down’ button until desired value is displayed. 

  Press ‘Mode/Set’ button to set the value. 

  Press ‘Up’ or ‘Down’ button until <th> is displayed. 

  Press ‘Verify” button to return to display cabinet temperature. 

 
Setting Forced Defrost- 

To start a forced defrost; 

  Press ‘Mode/Set’ button. 

  Press ‘Up’ or ‘Down’ button until <dF> is displayed. 

  Press ‘Manual DF’ for 2 seconds to start a forced defrost. 

 
To stop a forced defrost; 
During a forced defrost, press ‘Manual DF’ button for 2 seconds to stop a forced defrost.  
<dF> will flash five times and then return to normal operation. 
 

TROUBLESHOOTING 

 

Problem Possible 

Cause 

Remedy 

Power connection failure 

Check power cord and plug it in 

Compressor will 
not start 

Power switch is in ‘off’ position 

Move it to ‘on’ position 

Temperature set point is too high 

Correct temperature set point 

The door is opened too frequently

 

Loading of too much warm or 
moist product 

 

Not enough ventilation 

Move the unit in a well ventilated 
place with at least 7 inches of 
clearance on all sides 

The unit does not 
refrigerate well 

Condenser is clogged 

Clean it 

Condensation on 
cabinet exterior 

High humidity air can result in 
condensation 

Wipe with cloth 

7/10   Rev. A   146527 

5

Содержание F23-S

Страница 1: ...e unit The casters with the brakes should be installed on the front of the unit For proper drainage of condensate the unit should be level when placed in its permanent location Leveling shims are included in the accessories package in the cabinet Loosen the casters and insert shims between caster and bottom of the unit Retighten the caster The exterior of the cabinet and doors have been protected ...

Страница 2: ...w 14 F freezer or 50 F refrigerator when the unit is plugged in there will be a three minute delay before the compressor will start The interior light will come on when a door is opened Whenever a door is opened the door open light on the display will be lit and the evaporator fans will stop The fans will start three seconds after the door is closed If a door is open for more than 30 seconds the d...

Страница 3: ...condenser coil disconnect the unit from power Periodic cleaning of the condenser coil will aid the heat transfer of the refrigeration system and increase its efficiency Cleaning is recommended a minimum of every 6 months To accomplish this remove the lower front grill from the cabinet The condenser coil is located behind the grill Use a soft bristled brush to remove any dirt particles that are on ...

Страница 4: ... button to return to display cabinet temperature Setting Temperature Differential The temperature differential is the amount of swing that the cabinet temperature does either side of the temperature set point If the temperature set point is 36 F and the temperature differential is 8 F the compressor will start when the control shows 40 F and stop when the control shows 32 F The default temperature...

Страница 5: ...fy button to return to display cabinet temperature Setting Forced Defrost To start a forced defrost Press Mode Set button Press Up or Down button until dF is displayed Press Manual DF for 2 seconds to start a forced defrost To stop a forced defrost During a forced defrost press Manual DF button for 2 seconds to stop a forced defrost dF will flash five times and then return to normal operation TROU...

Страница 6: ...2 Compressor 1 2HP 3 4HP 1 1HP 3 8HP 3 8HP 1 2HP Power Voltage 115V 115V 115 208 230V 115V Plug In Installation NEMA 5 15P NEMA 14 20P NEMA 5 15P Amps 8 5A 9 5A 9 0A 7 5A 7 5A 10 0A Range of Temperature Below 0 F 32 40 F Refrigerant R404a R134a Net Weight lb 295 499 622 288 475 609 Above specifications are subjected to change without prior notice for quality improvement The nameplate includes Seri...

Отзывы: