The refrigeration system located at the bottom of the unit requires free air access for 
proper operation.  Allow a minimum of seven inches between the back of the cabinet 
and the wall.  Do not locate the unit next to heat generating equipment or in direct 
sunlight.     
 
Confirm that the proposed electrical outlet has the correct voltage, frequency and 
current carrying capacity for the requirements of the unit.  This information is noted on 
the data plate on the inside left wall of the unit.  The unit should be isolated on a circuit.  
Do not use an extension cord to get power to the unit.  Improper electrical installations 
will void the compressor warranty. 

 

OPERATION 

Once the unit is connected to the proper power supply, the display panel will be lit for 
two (2) seconds followed by a beep, and then the cabinet temperature will be displayed 
and the compressor will start to run.  The compressor is running whenever ‘comp’ is lit 
on the display.  If the cabinet temperature is higher than 68˚F (refrigerator) or 14˚F 
(freezers) the display will read <Hi> and lower than14˚F (refrigerator) or -50˚F (freezer) 
the display will read <Lo>.  If the unit does not start immediately, check the power 
switch located on the bottom of the top grill.  If the cabinet temperature is below 14˚F 
(freezer) or 50˚F (refrigerator) when the unit is plugged in there will be a three minute 
delay before the compressor will start. 
 
The interior light will come on when a door is opened.  
 
Whenever a door is opened the door open light on the display will be lit and the 
evaporator fans will stop.   The fans will start three seconds after the door is closed.  If a 
door is open for more than 30 seconds, the door open alarm will beep two times.  If a 
door is open more than 60 seconds, the alarm beeps five times and if open more than 
five minutes the alarm will beep continuously.  
 
The electronic control has an alarm function to remind the operator to periodically clean 
the condenser coil.  The condenser coil will collect dust and debris during normal 
operation.  If left unclean, this will lead to poor performance, high energy consumption 
and possible compressor failure.  Warranties do not cover failures related to condenser 
cleaning.  At 6 month intervals the display will blink “CL” and the buzzer will sound to 
remind the operator to clean the condenser coil.  After one hour the buzzer will stop but 
the display will continue to blink “CL”.  Refer to the ‘MAINTENANCE’ section of this 
manual to learn how to clean the condenser coil.  The electronic control can be reset to 
normal operation by pressing the ‘Mode’ and ‘Verify’ buttons at the same time for five 
seconds.  Depending on conditions, the condenser coil may require more frequent 
cleaning.     
 
 
 
 
 
 
 
 

7/10   Rev. A   146527 

2

Содержание F23-S

Страница 1: ...e unit The casters with the brakes should be installed on the front of the unit For proper drainage of condensate the unit should be level when placed in its permanent location Leveling shims are included in the accessories package in the cabinet Loosen the casters and insert shims between caster and bottom of the unit Retighten the caster The exterior of the cabinet and doors have been protected ...

Страница 2: ...w 14 F freezer or 50 F refrigerator when the unit is plugged in there will be a three minute delay before the compressor will start The interior light will come on when a door is opened Whenever a door is opened the door open light on the display will be lit and the evaporator fans will stop The fans will start three seconds after the door is closed If a door is open for more than 30 seconds the d...

Страница 3: ...condenser coil disconnect the unit from power Periodic cleaning of the condenser coil will aid the heat transfer of the refrigeration system and increase its efficiency Cleaning is recommended a minimum of every 6 months To accomplish this remove the lower front grill from the cabinet The condenser coil is located behind the grill Use a soft bristled brush to remove any dirt particles that are on ...

Страница 4: ... button to return to display cabinet temperature Setting Temperature Differential The temperature differential is the amount of swing that the cabinet temperature does either side of the temperature set point If the temperature set point is 36 F and the temperature differential is 8 F the compressor will start when the control shows 40 F and stop when the control shows 32 F The default temperature...

Страница 5: ...fy button to return to display cabinet temperature Setting Forced Defrost To start a forced defrost Press Mode Set button Press Up or Down button until dF is displayed Press Manual DF for 2 seconds to start a forced defrost To stop a forced defrost During a forced defrost press Manual DF button for 2 seconds to stop a forced defrost dF will flash five times and then return to normal operation TROU...

Страница 6: ...2 Compressor 1 2HP 3 4HP 1 1HP 3 8HP 3 8HP 1 2HP Power Voltage 115V 115V 115 208 230V 115V Plug In Installation NEMA 5 15P NEMA 14 20P NEMA 5 15P Amps 8 5A 9 5A 9 0A 7 5A 7 5A 10 0A Range of Temperature Below 0 F 32 40 F Refrigerant R404a R134a Net Weight lb 295 499 622 288 475 609 Above specifications are subjected to change without prior notice for quality improvement The nameplate includes Seri...

Отзывы: