Installation
97
EN
Burner and nozzle characteristics tables
1 Natural gas G20
AUX
SR
R
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
72
97
115
133
Pre-chamber (printed on nozzle)
(X)
(Z)
(Y)
(S)
Reduced flow rate (W)
400
500
800
1600
2 Natural gas G20
AUX
SR
R
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
72
94
113
128
Pre-chamber (printed on nozzle)
(X)
(Z)
(H8)
(S)
Reduced flow rate (W)
400
500
800
1600
3 Natural gas G25
AUX
SR
R
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
72
94
121
138
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F2)
(F3)
Reduced flow rate (W)
400
500
800
1600
4 Natural gas G25.1
AUX
SR
R
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
77
100
134
145
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F3)
(F3)
Reduced flow rate (W)
400
500
800
1600
5 Natural gas G25
AUX
SR
R
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
77
100
134
145
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F3)
(F3)
Reduced flow rate (W)
400
500
800
1600
6 Natural gas G2.350
AUX
SR
R
UR-3c
Rated heating capacity (kW)
1.0
1.8
3.0
3.6
Nozzle diameter (1/100 mm)
94
120
165
200
Pre-chamber (printed on nozzle)
(Y)
(Y)
(F3)
(H3)
Reduced flow rate (W)
400
500
800
1600
Содержание CX60SV9
Страница 9: ...Description 63 EN 2 Description 2 1 General Description...
Страница 12: ...Description 66 2 3 Control panel...