Installation
98
The nozzles not provided are available at Authorised Service Centres.
7 LPG G30/31
AUX
SR
R
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
50
65
85
94
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced flow rate (W)
400
500
800
1600
Rated flow rate G30 (g/h)
76
131
218
255
Rated flow rate G31 (g/h)
75
129
214
250
8 LPG G30/31
AUX
SR
R
UR-3c
Rated heating capacity (kW)
1.1
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
50
65
81
91
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced flow rate (W)
450
550
800
1600
Rated flow rate G30 (g/h)
80
131
218
255
Rated flow rate G31 (g/h)
79
129
214
250
9 LPG G30/31
AUX
SR
R
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
43
58
70
75
Pre-chamber (printed on nozzle)
(H2)
(M)
(Y)
(F4)
Reduced flow rate (W)
400
500
800
1600
Rated flow rate G30 (g/h)
76
131
218
255
Rated flow rate G31 (g/h)
75
129
214
250
10 Town gas G110
AUX
SR
R
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.0
3.4
Nozzle diameter (1/100 mm)
145
185
260
315
Pre-chamber (printed on nozzle)
8
2
3
13
Reduced flow rate (W)
400
500
800
1200
WARNING:
In the case of conversion to
Town Gas G110 – 8 mbar (category
1a)
, do not use the burners provided, but request the special
G110 burners kit
from our Technical Assistance Service.
Содержание CX60SV9
Страница 9: ...Description 63 EN 2 Description 2 1 General Description...
Страница 12: ...Description 66 2 3 Control panel...