Instructions for the installer
12
4.2
Burner and nozzle characteristics table
Burner
Rated
heating
capacity
(kW)
LPG
GAS
–
G30/G31
28/37
mbar
Nozzle
diameter
1/100 mm
Reduced
capacity
(W)
Capacity
g/h G30
Capacity
g/h G31
Auxiliary
1
50
350
73
71
Semi-rapid
1.75
65
450
127
125
Rapid
3
85
800
218
214
Triple crown (4)
3.2
91
1500
233
229
Triple crown (8)
3.2
94
1500
233
229
Fish burner
1.9
68
800
138
136
Maxi oven
5.2
110
1200
378
371
Large grill
4.0
100
//
291
286
Burner
Rated
heating
capacity
(kW)
NATURAL GAS –
G20
20
mbar
Nozzle diameter
1/100 mm
Reduced capacity
(W)
Auxiliary
1
72
350
Semi-rapid
1.75
97
450
Rapid
3
115
800
Triple crown (4)
3.5
133
1500
Triple crown (8)
3.5
140
1500
Fish burner
1.9
94
800
Maxi oven
5.2
164
1200
Large grill
4.0
150
//