Instructions for the Installer

9

4. WALL FIXING AND ANTI-TIP DEVICE

  WARNING

 

-  All ranges can tip

-  Injury to persons could result

-  Install anti-tip device packed with the range

See installation instructions

FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN DEATH OR
SERIOUS BURNS TO CHILDREN OR ADULTS.

  WARNING

 

ELECTRIC SHOCK HAZARD

-  Use extreme caution when drilling holes into the wall or floor. There may be

concealed electrical wires located behind the wall or under the floor.

-  Identify the electrical circuits that could be affected by the installation of the

Anti-Tip Device, then turn off power to these circuits.

-  Failure to follow these instructions may result in electrcal shock or other

personal injury.

CAUTION: 

PROPERTY DAMAGE

-  Contact a qualified installer or contractor to determine the proper method fro drilling holes through the

wall or floor material (such as ceramic tile, hardwood, etc.)

-  Failure to follow these instructions may result in damage to wall or floor coverings.

4.1 Instructions for wall mounting

The anti tip brackets are to be attached to the rear wall as shown. The height of the bracket location from
the floor is determined after the range legs have been adjusted to the installation height as shown in the
installation instructions and the range has been leveled.

1 Level the range

using the front
adjustable
leveling legs.

2 From the floor,

measure the height
of the notch found
on the bracket. This
notch corresponds
to the centerline of
the holes for the
screws that will
fasten the brackets
to the wall.

Содержание A1XCU6

Страница 1: ...and 11 5 ELECTRICAL CONNECTION 12 5 1 US installation only 3 wire branch circuit 13 5 2 US installation and canadian installation 4 wire branch circuit 14 NOTE THIS APPLIANCE MUST BE INSTALLED SOLELY...

Страница 2: ...f not avoided may result in minor or moderate injury All safety messages will inform you as to potential hazards inform you on how to reduce the risk of injury and as to what can occur if the instruct...

Страница 3: ...national ANSI NFPA 70 ELECTRICAL CODE LATEST EDITION or the CSA STANDARD C22 1 CANADIAN ELECTRICAL CODE PART 1 LATEST EDITION and all local codes and ordinances for the kilowatt rating of the range B...

Страница 4: ...mm copper When installed in a 24 61 cm base cabinet with 25 63 5 cm countertop front of oven door protrudes 1 7 8 4 8 cm beyond 24 61 cm base cabinet 30 76 2 cm min clearance between the top of the co...

Страница 5: ...to be installed must be sealed Some cabinet and building materials are not designed to withstand the heat produced by the oven for baking Check with your builder or cabinet supplier to make sure that...

Страница 6: ...ted uniformly across the bottom After transporting the professional range close to its final location the range can be tipped back and supported on the rear legs while the dolly is carefully removed T...

Страница 7: ...electrcal shock or other personal injury CAUTION PROPERTY DAMAGE Contact a qualified installer or contractor to determine the proper method fro drilling holes through the wall or floor material such...

Страница 8: ...example screws appropriate for the type of the wall Adhere scrupulously to the heights indicated in the figures A using the appliance s dimensions as a guide Type of screw recommended 1 4 A1XCU6 35 7...

Страница 9: ...ing screws C WARNING ELECTRIC SHOCK HAZARD Disconnect power to the junction box before making connection Electrically ground the appliance with green or green yellow colored wire Do not ground to a ga...

Страница 10: ...t rating of the range Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley...

Страница 11: ...in doubt as to whether the appliance is properly grounded Do not modify the power supply cord If it will not fit the outlet have a proper outlet installed by a qualifies electrician 5 1 US installati...

Страница 12: ...ance to the neutral white colored wire wire in the junction box pic 2 NOTE FOR MODEL RATED UP TO 4 3 KW CONNECT TO A 20A FUSE OR CIRCUIT BREAKER FOR MODEL RATED FROM 4 4 KW TO 6 6 KW CONNECT TO A 30A...

Отзывы: