Table of Contents

1. IMPORTANT SAFETY INSTRUCTIONS ................................................................................. 4
2. DIMENSIONAL REQUIREMENTS  .......................................................................................... 6

2.1 Product dimension ............................................................................................................. 7

3. UNPACKING, MOVING AND PLACING THE RANGE  ........................................................... 8
4. WALL FIXING AND ANTI-TIP DEVICE  ................................................................................... 9

4.1 Instructions for wall mounting ............................................................................................ 9
4.2 Mounting the rear top upstand ......................................................................................... 11

5. ELECTRICAL CONNECTION  ............................................................................................... 12

5.1 US installation only / 3-wire branch circuit ....................................................................... 13
5.2 US installation and canadian installation / 4-wire branch circuit ...................................... 14

NOTE:  THIS APPLIANCE MUST BE INSTALLED SOLELY AND EXCLUSIVELY BY A QUALIFIED
TECHNICIAN. ANY TECHNICAL PROCEDURES MUST BE CARRIED OUT BY AN AUTHORIZED
TECHNICIAN.

INSTRUCTIONS FOR THE INSTALLER:

 these are intended for the 

qualified engineer

 who is able to

install, commission and test the appliance

3

Содержание A1XCU6

Страница 1: ...and 11 5 ELECTRICAL CONNECTION 12 5 1 US installation only 3 wire branch circuit 13 5 2 US installation and canadian installation 4 wire branch circuit 14 NOTE THIS APPLIANCE MUST BE INSTALLED SOLELY...

Страница 2: ...f not avoided may result in minor or moderate injury All safety messages will inform you as to potential hazards inform you on how to reduce the risk of injury and as to what can occur if the instruct...

Страница 3: ...national ANSI NFPA 70 ELECTRICAL CODE LATEST EDITION or the CSA STANDARD C22 1 CANADIAN ELECTRICAL CODE PART 1 LATEST EDITION and all local codes and ordinances for the kilowatt rating of the range B...

Страница 4: ...mm copper When installed in a 24 61 cm base cabinet with 25 63 5 cm countertop front of oven door protrudes 1 7 8 4 8 cm beyond 24 61 cm base cabinet 30 76 2 cm min clearance between the top of the co...

Страница 5: ...to be installed must be sealed Some cabinet and building materials are not designed to withstand the heat produced by the oven for baking Check with your builder or cabinet supplier to make sure that...

Страница 6: ...ted uniformly across the bottom After transporting the professional range close to its final location the range can be tipped back and supported on the rear legs while the dolly is carefully removed T...

Страница 7: ...electrcal shock or other personal injury CAUTION PROPERTY DAMAGE Contact a qualified installer or contractor to determine the proper method fro drilling holes through the wall or floor material such...

Страница 8: ...example screws appropriate for the type of the wall Adhere scrupulously to the heights indicated in the figures A using the appliance s dimensions as a guide Type of screw recommended 1 4 A1XCU6 35 7...

Страница 9: ...ing screws C WARNING ELECTRIC SHOCK HAZARD Disconnect power to the junction box before making connection Electrically ground the appliance with green or green yellow colored wire Do not ground to a ga...

Страница 10: ...t rating of the range Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley...

Страница 11: ...in doubt as to whether the appliance is properly grounded Do not modify the power supply cord If it will not fit the outlet have a proper outlet installed by a qualifies electrician 5 1 US installati...

Страница 12: ...ance to the neutral white colored wire wire in the junction box pic 2 NOTE FOR MODEL RATED UP TO 4 3 KW CONNECT TO A 20A FUSE OR CIRCUIT BREAKER FOR MODEL RATED FROM 4 4 KW TO 6 6 KW CONNECT TO A 30A...