Instructions for the installer
32
For operation on 400-415V3N
∼∼∼∼
:
use an
H05RR-F-type five-core cable (5 x 2.5 mm
2
).
For operation on 400-415V2N
∼∼∼∼
:
use an
H05RR-F-type four-core cable (4 x 4 mm
2
).
For operation on 230-240V
∼∼∼∼
:
use an
H05RR-F-type three-core cable (3 x 6 mm
2
).
The cable end to be connected to the
appliance must be provided with an ground
wire (yellow-green) at least 20 mm longer.
Complete wiring up to power supply with an appropriately rated five-core
plug (see data plate) or, in case of operation from a
230V
∼∼∼∼
power supply,
with a three-core plug. Make sure that plug and wall socket are of the
same type and are in conformity with regulations in force. Make sure that
the appliance is properly earthed. Before powering, check that the power
line is properly earthed. Avoid using adapters or shunters.
The manufacturer declines all responsibility
for damage to persons
or things caused by non-observance of the above prescriptions or by
interference with any part of the appliance.
2.2 Levelling
Adjust the four feet so as to set the appliance on a perfectly level plane.
For this purpose, loosen the lock nut and unscrew the foot. The range of
adjustment of the screw is 10 mm.