Hook
Crimping area
Core wire
crimping area
Socket
(DXT170-71-1)
Core wire
Insulation
Lead wire
Manual override
(Blue)
Adapter plate
Pilot valve
(V111)
Conversion connector
assembly
[New]
VQZ1000V-85-
A
Coil voltage
1
2
3
4
24/12 VDC
100 VAC
200 VAC
Other AC voltages
Manual override
(Orange)
Adapter plate
Pilot valve
(VQ111)
0.2 to 0.33 mm
2
Max. cover diameter: ø1.7 mm
Lead Wire Connection
Caution
1. Crimping of lead wires and sockets
Not necessary if ordering the lead wire pre-connected model.
Strip 3.2 to 3.7 mm at the end of the lead wires, insert the
ends of the core wires evenly into the sockets, and then crimp
with a crimping tool. When this is done, take care that the
coverings of the lead wires do not enter the core wire crimping
area.
2. Attaching and detaching sockets with lead
wires
Attaching
Insert the sockets into the square holes of the connector ( ,
indication), and continue to push the sockets all the way in
until they lock by hooking into the seats in the connector.
(When they are pushed in, their hooks open and they are
locked automatically.) Then, confirm that they are locked by
pulling lightly on the lead wires.
Detaching
To detach a socket from a connector, pull out the lead wire
while pressing the socket’s hook with a stick having a thin tip
(approx. 1 mm). If the socket will be used again, first spread
the hook outward.
Connector
Lead wire
Socket
Hook
1. When replacing a conventional type valve
with a new type for maintenance or other
reasons, a “conversion connector assem-
bly” is necessary to convert the connector
from 3 terminals to 2 terminals and must be
ordered separately. (When ordering, refer to
the below part nos.)
For pilot valves, there is no compatibility between the conven-
tional type and new type. When replacing a pilot valve, be
sure to confirm whether it is the new type or the conventional
type.
Pilot Valve Replacement
Caution
[Conventional]
Series
VQZ
Specific Product Precautions 2
Be sure to read before handling.
Refer to front matter 53 for Safety Instructions and pages 3 to 8 for 3/4/5 Port
Solenoid Valve Precautions.
(Please contact SMC for the crimping tools.)
1827
SYJ
VQZ
VP
VG
VP3
VQZ