SMC Networks VQZ100 Series Скачать руководство пользователя страница 36

<Gasket and screw assembly>

VQZ100-GS-5

VQZ200-GS-5

VQZ300-GS-5

VQZ100
VQZ200
VQZ300

VQZ100
VQZ200
VQZ300

VVQ1000-50A-C3

VVQ1000-50A-C4

VVQ1000-51A-C4

VVQ1000-50A-C6

VVQ1000-51A-C6

VVQ2000-51A-C6

VVQ1000-51A-C8

VVQ2000-51A-C8

VVQ2000-51A-C10

C3

C4

C6

C8

C10

Fitting size

Model

One-touch Fitting Assembly (for Cylinder port)

Note) Purchasing order is available in units of 10 pieces. 

VVQ1000-50A-M5

M5 (VQZ100 only)

Part no.

Model

Note) The above part numbers are for 10 valves 

(a set of 10 gaskets and 20 screws).

<Plug connector assembly>

Lead wire length

Nil

  300 mm
  600 mm
1000 mm
1500 mm
2000 mm
2500 mm
3000 mm
5000 mm

6

10
15
20
25
30
50

SY100-30-4A-

SY100-30-1A-

SY100-30-2A-

SY100-30-3A-

SY100-30-A

How to Order 
Include the connector assembly part number together with the part 
number for the plug connector’s solenoid valve without connector.

AC
VQZ115-1LO1-M5
SY100-30-1A-20

DC
VQZ115-5LO1-M5
SY100-30-4A-20

Example) In case of 2000 mm of lead wire

V111

<Pilot valve assembly>

5 G

Manual override

None (Applicable to VQZ200/300)
Yes (Applicable to VQZ100)

Nil

M

V115

X110

<DIN terminal type (Applicable to the VQZ200/300)>

5 Y

Function

Electrical entry

Coil voltage

100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC

1
2
3
4
5
6

Electrical entry

Valve model

Pilot valve model

VQZ115

-

L

1

VQZ115

-

M

1

V111

M-

M

V111

M-

L

Note) The electrical entry (L, M) for the VQZ100 pilot valve is different from that of the 

main valve model number.

Grommet (DC specification)
L-type plug connector with lead wire
L-type plug connector without connector
M-type plug connector with lead wire
M-type plug connector without connector

G

LU

LOU

MU

MOU

LZ

LOZ

MZ

MOZ

Light/surge voltage
suppressor

None

Yes

Electrical entry

Symbol

DC

AC

Coil voltage

100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC

1
2
3
4
5
6

Note) Semi-standard

When replacing only the pilot valve assembly, use caution 
because it is not possible to convert to a V115 (DIN terminal) 
from a V111 (Grommet, L-type, M-type), or vice versa.

Caution

Function

Standard
High speed response type
(Applicable to VQZ200/300)
High pressure type (Applicable to
Metal seal type, Poppet seal type)

Nil

Note)

Note)

Symbol

Specifications

DC


(0.35 W)

(0.9 W)

(0.9 W)

AC

Manual override 

(Applicable to the VQZ100)

Non-locking push type
Locking slotted type

Nil

B

 Thread type

<Sub-plate>

Model

Sub-plate part no.

For internal pilot

For external pilot

VQZ100
VQZ200
VQZ300

01

02

VQZ100-S-01

VQZ200-S-

VQZ300-S-

(-Q)

(-Q)

(-Q)

-R (-Q)

-R (-Q)

-R (-Q)

02

03

VQZ100-S-01

VQZ200-S-

VQZ300-S-

01

02
02

03

Series 

VQZ

Replacement Parts

Base Mounted

DC:

100 VAC:

200 VAC:

Other AC voltages:

Without lead wire:

(with connector and 2 sockets only)

Standard

High speed response type
High pressure type
(Metal seal type only)

Nil

Note)

Note)

Symbol

Specifications

DC


(0.35 W)

(0.9 W)

(0.9 W)

AC

Note) Semi-standard

DIN terminal 
DIN terminal without connector
DIN terminal with light/surge voltage suppressor 
DIN terminal with surge voltage suppressor (DC specification)
DIN terminal with surge voltage suppressor, without connector 

(DC specification)

Y

YO

YZ

YS 

Note)

YOS 

Note)

Light/surge

voltage

suppressor

None

Yes
Yes

(Without

 light)

Electrical entry

Symbol

Note) For AC voltage valves there is no “S” option. It is already built-in to the rectifier circuit.

1824

A

Содержание VQZ100 Series

Страница 1: ...type High speed response type 0 35 0 9 VQZ100 VQZ200 VQZ300 VQZ100 VQZ200 VQZ300 10 15 18 10 15 18 1 3 2 4 2 0 3 2 0 56 Poppet 1 7 3 0 1 0 Poppet 3 0 4 1 Series Valve width mm Metal seal C dm3 s bar F...

Страница 2: ...ssor Manual override 3 port Body ported 3 port Base mounted 2 0 3 0 Poppet 1 0 Rubber Metal 1 3 1 7 2 4 3 0 Poppet 0 56 Rubber Metal 3 2 4 1 N C N O Except VQZ100 Standard 12 VDC 24 VDC Option 100 VAC...

Страница 3: ...10A 5 for VQZ100 VVQZ200 10A 5 for VQZ200 VVQZ300 10A 5 for VQZ300 Blanking plug KQ2P 23 KQ2P 04 KQ2P 06 KQ2P 08 KQ2P 10 DIN rail AXT100 DR Silencer for EXH port Port plug VVQZ100 CP for VQZ100 Base...

Страница 4: ...6 100 VAC 50 60 Hz 200 VAC 50 60 Hz 110 VAC 115 VAC 50 60 Hz 220 VAC 230 VAC 50 60 Hz 24 VDC 12 VDC CE compliant C3 C4 C6 M5 PR Option Note For applicable One touch fitting and silencer models for thi...

Страница 5: ...External pilot type Metal seal type only KR Note 1 2 High speed response External pilot type BR Note 1 2 0 9 W 0 9 W IP65 compliant Nil W Note Compliant Note VQZ200 300 DIN terminal rubber seal only...

Страница 6: ...2 2 2 9 0 30 0 24 0 37 0 20 0 36 0 28 0 33 0 16 0 27 0 14 0 33 0 45 0 31 0 45 0 56 0 72 0 49 0 69 C dm3 s bar b Cv C dm3 s bar b Cv 10 or less 22 or less 22 or less 22 or less 22 or less 22 or less 33...

Страница 7: ...4 Component Parts N C N C N O N O Description Body Spool valve Pilot valve assembly P R plate Material Resin Aluminum HNBR Resin Aluminum Note VQZ100 12A Standard VQZ100 12B External pilot type Note...

Страница 8: ...r mounting 30 2 M5 x 0 8 2 A port Lead wire length Approx 300 24 9 29 9 32 1 65 1 72 1 53 8 60 8 39 7 41 9 Lead wire length Approx 300 Dimensions VQZ100 Single Unit Grommet G VQZ115 G 1 C3 C4 C6 PR L...

Страница 9: ...7 For manifold mounting One touch fitting 2 A port Applicable tubing O D 4 5 32 6 1 4 M3 x 0 5 External pilot port For external pilot 11 20 5 19 3 3 5 Approx 300 69 2 47 34 1 8 2 A Dimensions VQZ200...

Страница 10: ...nal pilot port For external pilot 5 5 1 4 2 A port 38 5 Lead wire length 32 39 85 8 88 Approx 300 Lead wire length 76 78 2 Approx 300 43 3 50 3 71 Applicable cable O D 3 5 to 7 94 6 42 5 53 8 61 3 93...

Страница 11: ...uch fitting M5 thread Replaceable type C3 Symbol Electrical entry D D0 Note 1 R Note 2 1 Note 1 Order DIN rail separately For DIN rail part no refer to page 1805 Note 2 When two or more symbols are sp...

Страница 12: ...terminal DIN terminal DC specification DIN terminal without connector DC specification Light surge voltage suppressor CE compliant AC DC None Yes None Yes Yes Without light Electrical entry Symbol Not...

Страница 13: ...tion per station 37 VV3QZ12 VV3QZ22 VV3QZ32 VV3QZ22 05C 1 set C kit 5 station manifold base part no VVQZ200 10A 2 1 set Blanking plate assembly part no VQZ212 5M1 C6 4 sets N C type part no The asteri...

Страница 14: ...Z100 L type plug connector L M type plug connector M VV3QZ12 C Grommet G L1 L2 L3 L4 L5 L n 2 n Stations Max 20 stations Dimensions 85 5 75 43 5 21 30 5 3 85 5 75 54 16 41 4 98 87 5 64 5 17 51 5 5 110...

Страница 15: ...Max 20 stations Dimensions 85 5 75 54 16 43 3 110 5 100 70 20 5 59 4 123 112 5 86 18 5 75 5 135 5 125 102 17 91 6 148 137 5 118 15 107 7 173 162 5 134 19 5 123 8 185 5 175 150 18 139 9 198 187 5 166...

Страница 16: ...ons Max 20 stations Dimensions 98 87 5 61 18 5 49 3 110 5 100 80 15 5 68 4 135 5 125 99 18 5 87 5 148 137 5 118 15 106 6 173 162 5 137 18 125 7 198 187 5 156 21 144 8 210 5 200 175 18 163 9 235 5 225...

Страница 17: ...imension 20 260 5 19 248 18 235 5 17 223 16 210 5 15 198 14 185 5 13 173 12 160 5 11 148 10 135 5 9 123 8 110 5 7 98 6 85 5 5 73 4 60 5 3 48 2 35 5 1 23 No L dimension L Dimension L 7 5 25 35 VQZ100 V...

Страница 18: ...M3 x 0 5 VQZ200 M5 x 0 8 VQZ300 Pressure Specifications 100 kPa to 0 7 MPa Series Operating pressure range Note 1 Metal seal Rubber seal VQZ100 poppet VQZ100 Note 2 VQZ200 300 0 2 to 0 7 MPa 0 1 to 0...

Страница 19: ...o the VQZ200 300 5 Y Function Electrical entry Coil voltage 100 VAC 50 60 Hz 200 VAC 50 60 Hz 110 VAC 50 60 Hz 220 VAC 50 60 Hz 24 VDC 12 VDC 1 2 3 4 5 6 DIN terminal DIN terminal without connector DI...

Страница 20: ...sub plate part no refer to page 1824 Function 1 Standard High pressure type External pilot type High pressure External pilot type Nil K Note 1 R Note 1 2 Symbol Specifications DC Note 3 AC Note 1 Semi...

Страница 21: ...W Note Compliant Note VQZ200 300 DIN terminal rubber seal only except external pilot For details on IP65 enclosure refer to page 1823 Note For optional thread type refer to page 1823 VQZ200 300 How t...

Страница 22: ...17 0 46 0 18 0 43 0 21 0 42 0 21 0 45 0 23 0 38 0 65 0 38 0 67 0 70 1 3 0 72 1 2 0 35 0 20 0 40 0 21 0 30 0 27 0 36 0 16 0 38 0 25 0 45 0 80 0 39 0 74 0 80 1 0 0 69 1 2 Standard 0 35 W High pressure 0...

Страница 23: ...tal seal Rubber seal No 1 2 3 4 Metal seal type Rubber seal type N C N C N O N O Component Parts VQZ200 300 Poppet type N C Description Body Spool valve Pilot valve assembly Port plug Material Resin A...

Страница 24: ...ad wire length 7 7 5 16 35 5 14 5 Approx 300 40 9 30 5 24 3 5 34 41 3 5 53 8 38 4 2 A R 3 P 1 2 A Manual override 2 x 3 4 For mounting Dimensions VQZ100 Single Unit L type plug connector L VQZ115 L 1...

Страница 25: ...x 300 64 2 86 3 63 6 74 9 82 4 48 9 Pg7 Applicable cable O D 3 5 to 7 Max 10 85 4 45 5 Dimensions VQZ200 Single Unit Grommet G VQZ2 5 G 1 01 02 VQZ215 G 1 01 Unless otherwise indicated dimensions are...

Страница 26: ...prox 300 54 1 76 3 5 A 2 P 1 R 3 3 5 to 7 Max 10 94 9 86 3 78 8 67 5 54 1 94 58 4 Pg7 Applicable cable O D Dimensions VQZ300 Single Unit Grommet G VQZ3 5 G 1 M type plug connector M VQZ3 5 M 1 L type...

Страница 27: ...and side piping by the manifold specification sheet Note 3 For inch size One touch fittings refer to page 1823 Note 1 Semi standard Note 2 For details on external pilot type refer to page 1823 Note 3...

Страница 28: ...r consumption refer to page 1810 Function Nil Standard High speed response type External pilot type B Note 1 K Note 1 R Note 1 2 Symbol Specifications DC Note 3 AC High pressure External pilot type Me...

Страница 29: ...ons 126 Addition per station 38 2 stations 209 Addition per station 60 The asterisk denotes the symbol for assembly Prefix it to the part nos of the solenoid valve etc Add the valve and option part nu...

Страница 30: ...port M5 x 0 8 PE Pilot EXH port 8 15 46 5 13 4 16 3 41 2 11 Approx 300 44 9 45 2 66 L1 L2 L3 L4 L5 L n 2 n Stations Max 20 stations Dimensions 85 5 75 43 5 21 30 5 3 85 5 75 54 16 41 4 98 87 5 64 5 1...

Страница 31: ...Ported L type plug connector L M type plug connector M VV3QZ15 C Grommet G Stations Port size The dashed lines indicate the DIN rail mounting D L1 L2 L3 L4 L5 L n 2 n Stations Max 20 stations Dimensi...

Страница 32: ...L n 2 n Stations Max 20 stations Dimensions 85 5 75 52 17 42 3 98 87 5 68 15 58 4 123 112 5 84 19 5 74 5 135 5 125 100 18 90 6 148 137 5 116 16 106 7 173 162 5 132 20 5 122 8 185 5 175 148 19 138 9 1...

Страница 33: ...ax 20 stations Dimensions 98 87 5 66 16 48 3 123 112 5 86 18 5 68 4 148 137 5 106 21 88 5 160 5 150 126 17 5 108 6 185 5 175 146 20 128 7 198 187 5 166 16 148 8 223 212 5 186 18 5 168 9 248 237 5 206...

Страница 34: ...s of each kit 40 510 5 39 498 38 485 5 37 473 36 460 5 35 448 34 435 5 33 423 32 410 5 31 398 30 385 5 29 373 28 360 5 27 348 26 335 5 25 323 24 310 5 23 298 22 285 5 21 273 No L dimension 20 260 5 19...

Страница 35: ...on of the external pilot type VQZ Y W1 5 2 3 Entry is the same as standard products Thread type Cylinder port and 1 P 3 R ports Nil N T F Rc NPT NPTF G Cylinder port VQZ100 VQZ200 VQZ300 Cylinder port...

Страница 36: ...without connector M type plug connector with lead wire M type plug connector without connector G LU LOU MU MOU LZ LOZ MZ MOZ Light surge voltage suppressor None Yes Electrical entry Symbol DC AC Coil...

Страница 37: ...licable solenoid valve series VQZ200 300 How to Order Entry is the same as standard products VQZ Made to Order X90 Main valve fluororubber CE compliant Made to Order X30 Pilot valve common exhaust CE...

Страница 38: ...ver until it stops Release the screwdriver and the manual override will return Push down completely on the manual override button with a small screwdriver While down turn clockwise 90 to lock it Turn...

Страница 39: ...the connector When they are pushed in their hooks open and they are locked automatically Then confirm that they are locked by pulling lightly on the lead wires Detaching To detach a socket from a con...

Страница 40: ...y with the terminal screws 4 Secure the cord by fastening the ground nut 3 Changing the entry direction After separating the terminal block and housing the cord entry can be changed by attaching the h...

Страница 41: ...pulling the fitting assembly away from the valve base remove the clip then connect a tube or plug KQ2P with the One touch fitting and pull it out holding the tube or plug Do not hold the release bush...

Отзывы: