VQC
SQ
VQ0
VQ4
VQ5
VQZ
VQD
2-4-35
Series
VQ2000
Plug Lead Unit: Flip Type
Body Ported
How to Order Valves
C6
2 1 4 0 Y
5 L
VQ
2
VQ2000
2
1
2 position single
2 position double (latching)
Series
Type of actuation
Metal
seal
Rubber
seal
Seal
0
1
Metal seal
Rubber seal
Cylinder port
C4
C6
C8
Symbol
With One-touch fitting for ø4
With One-touch fitting for ø6
With One-touch fitting for ø8
Port size
Manual override
VQ2000
Electrical entry
Coil voltage
1
2
Note)
3
4
Note)
5
6
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC
Function
Manifold Option
How to Order Manifold Assembly
Example
VV5Q24-08FU2-D
∗
VQ2140-5LO-C6
∗
VQ2240-5LOB-C6
···
1 set (F kit 8 station manifold base no.)
···
4 sets (Single solenoid part no.)
···
4 sets (Double solenoid part no.)
Blanking plate assembly
VVQ2000-10A-4
Name plate [-N4]
VVQ2000-N4-Station
(1 to Max. stations)
Silencer (For EXH port)
Blanking plug
AN200-KM8
Individual SUP spacer
VVQ2000-P-4-C8
DIN rail mounting bracket
VVQ2000-57A-4
Block valve
VVQ2000-R-4-C8
Built-in silencer,
direct exhaust [-S]
Port plug
VVQ1000-58A
Individual EXH spacer
VQ2000-FPG-
Double check block
P
R
PR
0
1
1
2
VQ2 4 -
-
-
P
R
PR
KQ2P-
06
08
Specifications DC
(1.0 W)
(1)
(1.5 W)
(0.5 W)
AC
Symbol
Standard type
Nil
High pressure type
—
—
H
(2)
Low wattage type
Y
(2)
For power consumption
of AC type, refer to
page 2-4-36.
Except double (latching).
For negative common specifications, refer
to “Option” on page 2-4-69.
Connector assembly will be required when
the F, P, T, S kits add a valve.
For part nos., refer to “Option” on page 2-
4-69.
The C kits is applicable
to 200/220 VAC.
LO and MO valves are used for F,
P, T, and S kits. The plug
connector and lead wire are
attached to the manifold.
For inch-size One-touch
fittings, refer to “Option” on
page 2-4-69.
The asterisk denotes the symbol for assembly. Prefix it
to the part nos. of the solenoid valve, etc.
Please indicate manifold base type, corresponding valve,
and option parts. When entry of part numbers becomes
complicated, indicate on the manifold specification sheet.
Note)
G
: Grommet
C kit single only.
(Except AC)
L
: L plug
connector
With lead wire
M
: M plug
connector
With lead wire
LO
: L plug
connector
Without connector
MO
: M plug
connector
Without connector
With light/
surge voltage
suppressor
With light/
surge voltage
suppressor
With light/
surge voltage
suppressor
With light/
surge voltage
suppressor
Note 1)
Note 2)
Note 1)
Note 2)
Note)
Note)
A manual override for pilot valve is
provided to the standard model for
double type.
Note)
Nil
: Non-locking
push type
(Tool required)
B
: Locking
type (Tool required)
C
: Locking type
(Manual)
CB (SUP) port
One-touch fitting for ø8
CB (SUP) port
One-touch fitting for ø8
1 2 3 ················ Stations
D side
U side
D side
U side
D side
U side
Blocking indication label
3 m
Single solenoid (24 VDC)
VQ2140–5LO–C8 (4 sets)
Double solenoid (24 VDC)
VQ2240–5LOB–C8 (4 sets)
Manifold base (8 stations)
VV5Q24–08FU2–D
F kit
(D-sub connector)
D-sub
connector
cable
AXT100
–DS25–030
C8: One-touch
fitting for ø8
Individual EXH
spacer port size
EXH
outlet
Manual override body side
Pilot valve
Manual override
• For replacement parts, refer to page 2-4-
109.
P. 2-4-59