Special Wiring Specifications
Negative Common Specifications
Inch-size One-touch Fittings
Refer to following model no. for inch-size One-touch fittings.
Plug Connector Assembly Model
Connector Assembly Part No.
Example)
VV5Q14-09FS0-D
Others, option symbols:
to be indicated alphabetically.
How to order negative COM valves
VQ1140
Negative common specifications
N
5LO C6
F kit
(D-sub connector)
T kit
(Terminal block)
P kit
(Flat ribbon cable connector)
S kit
(Serial)
kit
Type
Max.
points
F
25P
U
S
F
15P
U
S
P
26P
U
S
P
20P
U
S
P
16P
U
S
P A
B
C
10P
U
S
A
S
14
8
8
16 16
16
16 16
14
F kit
D-sub connector
(25P)
P kit
Flat ribbon cable connector
(26P)
T kit
Terminal block
(16 terminals)
How to order manifold
How to order valves
VV5Q14
P, R port size
08FSO DN 00T
VQ1140
5
N7
Cylinder port
Symbol
Part no.
Specifications
Single
(2-wire)
ø1/4"
ø1/4"
ø5/16"
ø1/8" ø5/32"
ø5/16"
ø1/4"
N1
N3
N9
N7
T2
T1
VQ0000
VQ1000
VQ2000
VQ0000
A, B
port
VQ1000
VQ2000
M
13
14
Double (latching)
(3-wire)
Positive common
Negative common
Positive common
Negative common
AXT661-14A-F
AXT661-14AN-F
AXT661-13A-F
AXT661-13AN-F
Applicable tubing
O.D. (Inch)
—
—
—
—
—
Note)
Note)
Note)
Note) Due to the limitation of internal wiring.
In the internal wiring of F kit, P kit, T kit and S kit, double wiring
(connected to SOL. A and SOL. B) is adopted for each station
regardless of the valve and option types.
Mixed single and double wiring is available as an option.
1. How to order valves
Indicate an option symbol, -K, for the manifold no. and be sure
to specify the mounting position and number of stations of the
single and double wiring by means of the manifold
specification sheet.
2. Wiring specifications
Connector terminal numbers are connected from solenoid
station 1 on the A side in the order indicated by the arrows
without skipping any terminal numbers.
K S
3. Max. number of stations
The maximum number of stations depends upon the number
of solenoids. Assuming one for a single and two for a double,
determine the number of stations so that the total number is
not more than the maximum number given in the following
table.
Specify the valve model no. as shown below for negative COM
specification. The standard manifold no. can be used. Please
contact SMC for negative COM S kit.
Lead wire length: 300 mm
The parts numbers above are applicable to VQ0000/1000 (2 to 16
stations) and VQ2000 (2 to 10 stations). VQ2000 (11 to 16 stations)
uses AXT661- A(N) -F425.
Connector assembly will be required when the F, P, T, S kits add
a valve.
Specify the type of valve and connector assembly.
Note)
Note)
2-4-69
Series
VQ0000/1000/2000
Plug Lead Unit: Flip Type
Body Ported
VQC
SQ
VQ0
VQ4
VQ5
VQZ
VQD