How to Order Manifold
08
2 4
F
D
S1
VV5Q
4
2
Plug lead unit/Flip
VQ2000
Manifold
Series
Stations
01
1 station
···
···
Kit/Electrical entry/Cable length
None (C kit only)
DIN rail mounting style
Special wiring specifications (Except double wiring)
With name plate
Built-in silencer, direct exhaust
Option
D
(2)
K
(3)
N
S
(4)
Nil
F
kit
(D-sub connector)
T
kit
(Terminal block)
C
kit
(Connector)
S
kit
(Serial transmission unit)
P
kit
(Flat ribbon cable connector)
Connector entry direction
Top entry
Side entry
U0
U1
U2
U3
S0
S1
S2
S3
Without cable
With cable (1.5 m)
With cable (3 m)
With cable (5 m)
Max. 16
stations
(2)
(2)
(2)
Connector entry direction
Top entry
Side entry
U0
U1
U2
U3
S0
S1
S2
S3
Without cable
With cable (1.5 m)
With cable (3 m)
With cable (5 m)
Max. 16
stations
0
A
B
C
D
F1
H
Without SI unit
With general type SI unit (Series EX300)
Mitsubishi Electric Corp.: MELSECNET/MINI-S3 Data Link System
OMRON Corp.: SYSBUS Wire System
SHARP Corp.: Satellite I/O Link System
NKE Corp.: Uni-wire System (16 output points)
NKE Corp.: Uni-wire H System
Max. 16
stations
C
Connector kit
1
2
Applicable stations 1 to 8
Applicable stations 5 to 16
No. of terminals: 8, 1 row
No. of terminals: 16, 2 rows
Max. 16
Kit
T
Top entry
Side entry
25P
Note 1)
25P
Note 1)
26P
Note 1)
26P
Note 1)
Top entry
Side entry
The number of max. stations
differs from kit to kit.
(Refer to the table below.)
When two or more symbols are specified,
indicate them alphabetically. Example) -DNS
F, P, T, and S kits are of DIN rail include
suffix -D
Specify the wiring specifications in the
manifold specification sheet. (Except C kit)
F, P, T and S kits are provided with an
exhaust on one side, while C kits are with an
exhaust on both sides.
The valve is equipped
with an indicator
light/surge voltage
suppressor and the
voltage is 24 VDC.
The dust-protected type
SI unit is applicable, too.
For details, please
contact SMC.
Besides the above, F and P kits with different number of pins are available. For details, refer to page 2-4-68.
See page 2-4-69 for details.
Please consult with SMC for the following serial transmission kits: Matsushita Electric Works, Ltd.; Rockwell Automation, Inc.; SUNX Corporation; Fuji
Electric Co., Ltd.; OMRON Corporation.
Series
VQ2000
Body Ported
Plug Lead Unit: Flip Type
Note 1)
Note 2)
Note 3)
Note 4)
Kit
F
Kit
F
Kit
P
Kit
P
Kit
S
(3)
Note 1)
Note 2)
Note 3)
Simple specials are available with
SMC Simple Specials System. For
details about applicable models,
please contact SMC.
For details about certified products
conforming to international standards,
visit us at www.smcworld.com.
P. 2-4-38
P. 2-4-42
P. 2-4-46
P. 2-4-50
P. 2-4-54