Removal of manifold from DIN-rail (Fig 9)
Loosen the clamp screws
1
at both ends of the manifold. Lift side (a)
of the manifold base and slide the manifold in the direction of the fig-
ure (2).
Replacing the manifold onto the DIN-rail (Fig 9)
Hook side (b) onto the DIN rail. Press down side (a) to engage the
manifold onto the DIN rail. Tighten the two clamp screws
1
.
NOTE: Tightening torque is as follows:
0.8N-m ~ 1.2N-m (8 ~ 12 kgf/cm)
Replacement of cylinder port fittings (Fig 5b)
Remove and retain clip
K
from the valve body
L
. Remove fittings
2
from the valve body. Fit replacement fittings into valve body, pushing
them into the body until they stop. Replace the retaining clip
K
into
the valve body.
Replacing silencer element (Fig 10)
Remove element cover retaining screws
1
from both ends of the
manifold (retain). Remove both element end covers
2
and retain.
Remove and replace both silencer elements
3
, discard the originals.
Replace both element end covers. Re-fit element cover retaining
screws at both ends and tighten.
Plug lead unit/cassette type (Fig 15)
1
Valve
2
Fitting
3
Lower tie bolt
4
DIN-rail
5
Supply and exhaust block
6
Upper tie bolt
7
Solenoid pilot
8
Connector (electrical)
9
Collet
J
Direction arrow
K
Retaining clip (fittings)
L
Valve body
Fig 5b
Fig 10
Fig 9
Fig 15
Fig 13
Exploded view of plug-in unit/flip type manifold (Fig 13)
Fig 14
Exploded view of plug lead unit/flip type (Fig 14)
1
SI unit-omron
2
Flat cable kit
3
D-sub kit
4
D-side end plate
5
D-side end plate
6
D-side end plate
7
Junction box assembly
8
Gasket
9
Clip
J
Fitting assembly
K
Tie rod bolt
L
Junction cover
1
SI unit-omron
2
Flat cable kit
3
D-sub kit
4
Terminal block
5
Terminal block
6
D-side end plate assembly
7
U-side end plate assembly
8
Gasket
9
Tie rod bolt
J
Guide rod
D-sub connector
When you enquire about the product, please contact the following
SMC Corporation
:
ENGLAND
Phone 01908-563888
GERMANY
Phone 6103-402-0
ITALY
Phone 02-92711
FRANCE
Phone 1-64-76-10-00
HOLLAND
Phone 020-5318880
SWEDEN
Phone 08-603-07-00
SWITZERLAND
Phone 052-34-0022
AUSTRIA
Phone 02262-62-280
SPAIN
Phone 945-290600
IRELAND
Phone 01-4501822
GREECE
Phone 01-3426076
DENMARK
Phone 8738-0800
FINLAND
Phone 9-68-10-21
NORWAY
Phone 67-12-90-20
BELGIUM
Phone 03-3551464
POLAND
Phone 48-22-6131847
TURKEY
Phone 212-2211512
VQ Series
1
1
1
2
2
2
2
1
2
3
5
4
J
J
6
1 2
2
3
4
5
6
8
J
7
9
9
L
K
8
9
7
3
3
3
4
5
6
7
8
9
J
K
L
(a)
1
1
2
2
(b)
(a)
(b)
Hook
DIN
clamp
screw
Connector assembly
A, B port
R port
P port
25-pin
Type of
connection
D-side
U-side
Housing assembly and SI unit
D side end plate assembly
Valve and junction box assembly
U side end plate assembly
Station increase parts
Housing assembly and SI unit
Note 3)
D side end plate ass’y
Valve
U side end plate ass’y
Station increase
parts
S kit
P kit
F kit
L kit
S kit
P kit
F kit
T kit
FS (side entry)
Note 4)
PS (side entry)
Note 1)
Note 1: S kit is composed of a flat cable housing assembly (AXT100-2-PU20) of
1
SI unit and
2
P kit (20-pin).
Note 2
Connector assembly
Note 2
Connector
assembly
Note 2
Connector
assembly
Note 2
Connector
assembly
Note 4
Note 4
Note 4
PS (side entry)
FS (side entry)
Note 1
Note 1: S kit is composed of a flat cable housing assembly (AXT100-2-PU20) of
1
SI unit and
2
P kit (20-pin).
Note 2: Since no connector assembly is included, order it separately.