Light/Surge Voltage Suppressor
The varistor surge voltage suppressor has residual voltage
corresponding to the protective element and rated voltage;
therefore, protect the controller side from the surge voltage.
Valve EXH.[3(R)] port
Because of the residual pressure exhaust valve, if the valve EXH.[3(R)]
port is blocked, air will not be exhausted from the secondary side.
Size
Silencer
VP546E
AC30
AN30-03, AN302-03
VP746E
AC40
AN40-04, AN402-04
Built-in check valve
A check valve is built into the pilot flow path to suppress the pilot
pressure drop due to pressure fluctuation in the inlet side.
Be careful not to cause a dangerous situation due to air accumulated
between the check valve and the pilot valve.
Soft start-up function
When the soft start-up function is selected, the initial pressure of the
pneumatic system can be increased gradually.
●
Adjustment method
Turn the needle of the throttle valve to the left from fully closed (as
shipped) to adjust the initial speed of the drive equipment on the outlet
side.
Piping
Connection threads are not available for the residual pressure relief 3-port
solenoid valve.
Piping adapter and spacer with bracket must be ordered separately.
●
Piping Adapter
●
Spacer with Bracket
Please refer to the AC-D series/product-specific precautions for handling.
VP500, 700 Series / 3-Port Solenoid Valve Modular Type/
Residual Pressure Release Valve
3ポート残圧排気弁
Specific Product Precautions 2