3 Port Solenoid Valve

Series 

VP300/500/700

RoHS 

compliant

0.55 

w

1.55 

w

Built-in full-wave rectifier 

(AC)

Noise reduction

Noise is considerably reduced by changing it to DC mode via 

a full-wave rectifier.

Reduced apparent power

Conventional: 

5.6

 

VA

 

 

1.55

 

VA

Longer life expectancy:

50 million

 cycles or more 

(Conventional: 20 million cycles) 

 Based on SMC test conditions

Built-in strainer in the pilot valve 

Unexpected troubles due to foreign matter can be prevented. 

Note) Be sure to mount an air filter on the inlet side. 

Rubber material: HNBR

Ozone-resistant specification 

 The pilot valve poppet is made of FKM. 

Strainer

Electrical power waveform of energy saving type

Applied voltage

Standard

With power saving circuit

40 

ms

24 

V

V

1.55 

W

0.55

 W

W

Energy saving

Energy saving

Reduced power consumption: 

0.55 

[With power saving circui

t]

1.55 

[Standar

d] 

  (Conventional: 2.0 W) 

 

 With DC light

Power consumption reduced 

by power saving circuit.

Power consumption is decreased by approx. 1/3 by reducing 

the wattage required to hold the valve in an energized state. 

(effective energizing time is over 40 ms at 24 VDC.) Refer to 

electrical power waveform as shown below.

Series

 VP300

Air Operated Valve

Series

 VPA300/500/700

CAT.EUS11-97A-UK

Содержание VP300 Series

Страница 1: ...ide Rubber material HNBR Ozone resistant specification The pilot valve poppet is made of FKM Strainer Electrical power waveform of energy saving type Applied voltage Standard With power saving circuit...

Страница 2: ...O External pilot N C N O Port size Voltage Light surge voltage suppressor Manual override Electrical entry VP300 VP500 VP700 VP300 VP500 VP700 12 VDC 24 VDC 100 VAC 200 VAC 110 VAC 220 VAC 240 VAC P 1...

Страница 3: ...s EXH port type 2 to 20 stations 2 to 20 stations 2 to 20 stations Common EXH Individual EXH Common EXH Individual EXH Common EXH Individual EXH VV3P3 41 VV3P3 42 VV3P5 41 VV3P5 42 VV3P7 41 VV3P7 42 M...

Страница 4: ...PA500 VPA700 VPA300 VPA500 VPA700 P 25 P 30 1 8 1 4 1 4 3 8 3 8 1 2 1 8 1 4 1 4 3 8 3 8 1 2 4 2 8 9 15 3 3 8 8 8 15 0 Series VPA300 500 700 Model Selection by Operating Conditions e Air Operated Valve...

Страница 5: ...stations VV3PA3 41 VV3PA3 42 VV3PA5 41 VV3PA5 42 VV3PA7 41 VV3PA7 42 VPA300 VPA500 VPA700 P 35 Note Supply pressure to 1 P ports and exhaust air from 3 R ports on both sides for 10 stations or more Co...

Страница 6: ...uit DC only Body ported Note 1 Be sure to select the power sa ving circuit type when it is conti nuously energized for a long ti me Refer to back page 7 for de tails Note 2 T type is only available fo...

Страница 7: ...cation Mounting orientation Impact Vibration resistance m s2 Note Enclosure Standard High pressure type Standard High pressure type Pilot pressure range Note Impact resistance No malfunction occurred...

Страница 8: ...racket Note 2 These valves have been calculated according to ISO6358 and indicate the flow rate under standard conditions with an inlet pressure of 0 6 MPa relative pressure and a pressure drop of 0 1...

Страница 9: ...a G H L LN LO M MN MO Grommet Lead wire length 300 mm Grommet Lead wire length 600 mm With lead wire Without lead wire Without connector With lead wire Without lead wire Without connector Electrical e...

Страница 10: ...h 102 4 17 5 45 54 5 5 4 35 19 7 Indicator light Mounting groove for M5 thread 56 4 20 4 16 1 1 26 5 4 5 3 8 PE port Note 1 8 1 4 1 P 3 R port NO 3R 1P 20 9 Distance between ports Max 10 115 3 86 9 76...

Страница 11: ...0 7 25 6 1 4 3 8 1 P 3 R port 3 8 PE port Note NO 1P 3R 31 5 Distance between ports 89 2 79 2 79 2 69 2 Max 10 131 5 Pg9 Indicator light Applicable cable O D 4 5 to 7 Note Refer to page 24 when piping...

Страница 12: ...mounting 107 2 97 2 97 2 87 2 Max 10 154 5 Pg9 Indicator light Applicable cable O D 4 5 to 7 Note Refer to page 24 when piping to PE port is required 40 31 5 60 74 6 4 63 Indicator light Mounting groo...

Страница 13: ...10 VAC 115 VAC 220 VAC 230 VAC 240 VAC AC 50 60 Hz When using the surge voltage suppressor type residual voltage will remain Refer to back page 7 for details Caution Note 1 LN and MN types are with 2...

Страница 14: ...ctuation Internal pilot Operating pressure range MPa External pilot Operating pressure range MPa Ambient and fluid temperature C Max operating frequency Hz Manual override Pilot exhaust type Lubricati...

Страница 15: ...3 15 0 0 24 0 14 0 20 0 13 0 24 0 17 0 8 0 9 1 7 2 0 3 1 3 4 216 149 211 149 370 245 362 245 676 459 658 459 252 185 247 185 406 281 398 281 712 495 694 495 Note 1 valves Values without sub plate Note...

Страница 16: ...e 1 0 MPa G H L LN LO M MN MO Grommet Lead wire length 300 mm Grommet Lead wire length 600 mm With lead wire Without lead wire Without connector With lead wire Without lead wire Without connector Elec...

Страница 17: ...ounting Manual override 2A NO 1P NC NC 18 5 12 1 8 1 4 3 R port 3R 43 7 18 5 Indicator light 110 9 100 9 100 9 90 9 Max 10 105 3 Pg9 Indicator light Applicable cable O D 4 5 to 7 X Note Refer to page...

Страница 18: ...49 7 28 5 1 4 3 8 1 P port 1 8 External pilot port PE port Note 3 8 50 5 23 Indicator light 3R 23 13 5 1 4 3 8 3 R port Max 10 131 5 117 7 107 7 107 7 97 7 Pg9 Indicator light Applicable cable O D 4 5...

Страница 19: ...nting Manual override X 80 64 40 32 5 21 16 95 5 PE port Note 4 1 8 External pilot port 3 8 1 2 1 P port 16 40 3 8 1 2 2 A port 3R 24 16 3 8 1 2 3 R port 72 5 24 Indicator light Note Refer to page 24...

Страница 20: ...Applicable series 1 4 3 8 1 2 VP300 VP500 VP700 VV3P 3 3 42 04 02 Series 3 5 7 VP300 VP500 VP700 Thread type F N T Rc G NPT NPTF Stations 02 20 2 stations 20 stations Port size 02 03 04 Symbol Port s...

Страница 21: ...C 220 VAC 230 VAC 240 VAC AC 50 60 Hz When using the surge voltage suppressor type residual voltage will remain Refer to back page 7 for details Caution Note 1 LN and MN types are with 2 sockets Note...

Страница 22: ...ng 2 types of exhaust ports Common or individual exhaust type are available For individual exhaust type exhaust can be restricted Easy to change between N C and N O Type of actuation can be easily cha...

Страница 23: ...4 104 4 Max 10 105 3 Pg9 Indicator light Applicable cable O D 4 5 to 7 3R 1P Note Refer to page 24 when piping to PE port is required Series VP300 Dimensions Type 41 Common exhaust VV3P3 41 1 02 Grom...

Страница 24: ...30 5 24 50 13 5 17 5 M5 x 0 8 Common external pilot port External pilot specification R PE port Note 3 8 1 4 1 P port Note Refer to page 24 when piping to PE port is required Stationn L1 L2 2 83 5 68...

Страница 25: ...ort Note 3 8 M5 x 0 8 Common external pilot port External pilot specification R 3 8 1 P 3 R port Note Refer to page 24 when piping to PE port is required Stationn L1 L2 2 95 80 128 113 161 146 194 179...

Страница 26: ...O D 4 5 to 7 1P 1P 16 5 23 5 60 42 30 PE port Note 3 8 M5 x 0 8 Common external pilot port External pilot specification R 3 8 1 P port Note Refer to page 24 when piping to PE port is required L1 L2 9...

Страница 27: ...L1 Approx 300 Lead wire length 145 3 106 8 51 5 145 3 106 8 51 5 N C N O Pitch P 41 Station 1 Station n Manual override 2 x 8 5 For mounting Stationn L1 L2 2 115 99 3 156 140 4 197 181 5 238 222 6 27...

Страница 28: ...e length 145 3 106 8 51 5 145 3 106 8 51 5 2 x 8 5 For mounting N C N O Pitch P 41 Station 1 Station n Manual override Applicable cable O D 4 5 to 7 Applicable cable O D 4 5 to 7 Stationn L1 L2 2 115...

Страница 29: ...pilot exhaust port PE port is available when the valve is used in an environment where the exhaust from the pilot valve is not allowable or intrusion of ambient dust should be prevented VP 4 3 5 7 2 4...

Страница 30: ...ack page 8 for changing the type of actuation Note Impact resistance No malfunction occurred when tested in both the axial and right angle directions of main valve and armature tested in both energize...

Страница 31: ...no VP300 227 1A VP500 227 1A VP700 227 1A Bracket With 2 screws Model VPA342 VPA542 VPA742 12 A 2 1 P 3 R Body Adapter plate End plate Piston Spool valve Retainer Spring No 1 2 3 4 5 6 7 Description M...

Страница 32: ...16 5 54 5 45 5 4 35 1 8 12 PA port Mounting groove for M5 thread NO 3R 1P 3 53 7 26 5 4 5 16 20 4 M5 x 0 8 Breathing hole 1 8 1 4 1 P 3 R port 20 9 Distance between ports NO 3R 1P 3 53 7 26 5 4 5 16 2...

Страница 33: ...vacuum VPA542V 1 F 02 03 A B 12 22 5 60 50 45 5 4 1 8 12 PA port Mounting groove for M5 thread 12 22 5 60 50 45 5 4 1 8 12 PA port Mounting groove for M5 thread 46 45 40 31 5 4 39 6 23 5 2 x 4 2 For...

Страница 34: ...ing NO 3R 1P 3 100 8 42 30 5 40 9 3 8 1 2 1 P 3 R port M5 x 0 8 Breathing hole 43 Distance between ports Series VPA700 Body Ported Dimensions Standard VPA742 1 F 03 04 A B For vacuum VPA742V 1 F 03 04...

Страница 35: ...n resistance No malfunction occurred when tested in a one sweep test between 45 and 2000 Hz in both the axial and right angle directions of main valve and armature tested Specifications Flow Character...

Страница 36: ...P344 VP300 217 1 VP300 202 VP300 224 1 M3 x 36 Gasket Sub plate Note HNBR Aluminum die casted For valve mounting 8 9 Standard Caution M3 0 8 N m M4 1 4 N m M5 2 9 N m Port size How to Order Sub plate...

Страница 37: ...3R 18 5 12 1 8 1 4 3 R port X 60 59 24 12 39 19 5 1 8 1 4 1 P port M5 x 0 8 Breathing hole 12 19 5 1 8 1 4 2 A port 12 40 5 18 5 1 8 12 PA port 3R 18 5 12 1 8 1 4 3 R port Series VPA300 Base Mounted...

Страница 38: ...1 4 3 8 1 P port M5 x 0 8 Breathing hole NO 2A 1P NC NC 17 6 42 91 47 52 12 6 2 x 5 2 For mounting 13 5 28 5 1 4 3 8 2 A port 12 51 23 1 8 12 PA port 3R 23 13 5 1 4 3 8 3 R port For vacuum VPA544V 1...

Страница 39: ...athing hole 3 8 1 2 1 P port 2 x 6 2 For mounting NC NC 1P NO 2A 53 115 1 18 67 66 11 5 X 96 5 95 5 32 5 16 40 80 3 8 1 2 1 P port M5 x 0 8 Breathing hole 16 40 3 8 1 2 2 A port 3R 24 16 3 8 1 2 3 R p...

Страница 40: ...ype F N T Rc G NPT NPTF Stations 02 20 2 stations 20 stations Port size 02 03 04 Symbol Port size Applicable series 1 4 3 8 1 2 VPA300 VPA500 VPA700 Description Blanking plate assembly With a gasket a...

Страница 41: ...Indicate the valves to be attached below the manifold part number in order starting from station 1 as shown in the drawing VV3PA3 41 051 02 1 set Type 41 5 station manifold base part no VP300 25 1A 1...

Страница 42: ...5 16 17 18 19 20 Type 41 Common exhaust VV3PA3 41 1 02 Stations Type 42 Individual exhaust VV3PA3 42 3 02 Stations 12 NC 12 NO 65 2 58 2 65 2 58 2 26 2 26 2 28 7 5 L2 L1 Station n Station 1 N C N O 1...

Страница 43: ...Type 42 Individual exhaust VV3PA5 42 3 03 Stations 3R 1P 92 5 30 20 5 60 33 M5 x 0 8 Breathing hole 3 8 1 P 3 R port 12 NC 12 NO 91 83 41 1 91 83 41 1 7 5 31 L1 L2 Station n Station 1 N C N O 1 8 12...

Страница 44: ...n exhaust VV3PA7 41 1 04 Stations Type 42 Individual exhaust VV3PA7 42 3 04 Stations 12 NC 12 NO 115 1 107 1 51 5 115 1 107 1 51 5 8 37 L1 L2 N C N O 1 8 12 PA port Pitch P 41 Station n Station 1 2 x...

Страница 45: ......

Страница 46: ...erator who is appropriately trained and experienced 3 Do not service or attempt to remove product and machinery equipment until safety is confirmed 1 The inspection and maintenance of machinery equipm...

Страница 47: ...ease consult your nearest sales branch 2 For any failure or damage reported within the warranty period which is clearly our responsibility a replacement product or necessary parts will be provided Thi...

Страница 48: ...wnward with your thumb and pull the connector straight out 2 Crimping lead wires and sockets Strip 3 2 to 3 7 mm at the end of the lead wires insert the ends of the core wires evenly into the sockets...

Страница 49: ...it open separating the terminal block and the housing 3 Loosen the terminal screws on the terminal block insert the core of the lead wire into the terminal and attach securely with the terminal screws...

Страница 50: ...DC mode type with a surge voltage suppressor polar S and Z types connect wires to terminal 1 and 2 corresponding to the polarity or as shown on the figure on the right 3 Secure the cord by fastening t...

Страница 51: ...ge current Leakage voltage Valve R Power DC coil AC coil Especially when a resistor and a switching element are used in parallel or C R device surge voltage suppressor is used for the protection of th...

Страница 52: ...Caution With non polar type solenoid valves at times of sudden interruption of the loading power supply such as emergency shutdown surge voltage intrusion may be generated from loading equipment with...

Страница 53: ...1 Remove the body from the sub plate and reset the mark on the body corresponding to the N O mark on the sub plate as shown in the figure above 2 Remove the end plate from the body and rotate the end...

Страница 54: ......

Страница 55: ......

Страница 56: ...90 0 212 221 1519 E mail smc entek com tr http www entek com tr Poland SMC Industrial Automation Polska Sp z o o ul Poloneza 89 PL 02 826 Warszawa Phone 48 22 211 9600 Fax 48 22 211 9617 E mail offic...

Отзывы: